arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2407.20059cond-mat.mtrl-sciphysics.ins-det
收藏

利用等离激元能量膨胀测温法(PEET)提高TEM样品温度测量精度:解决样品厚度效应

Improving the Accuracy of Temperature Measurement on TEM samples using Plasmon Energy Expansion Thermometry (PEET): Addressing Sample Thickness Effects

Yi-Chieh Yang, Luca Serafin, Nicolas Gauquelin, Johan Verbeeck, Joerg R. Jinschek

AI总结:

本文研究PEET在钨薄片中测量室温至700°C局部温度时受30–70 nm厚度影响的问题,并利用体等离激元峰FWHM随厚度减小而展宽来提升变厚度样品的测温精度。

摘要:

分析型扫描透射电子显微镜(STEM)以及基于微电子机械系统(MEMS)的微型加热器的进展,使在高温下于纳米尺度开展原位材料表征成为可能。除了解析高温下的结构信息外,详细掌握样品内部的局部温度分布,对于揭示热诱导现象和过程也至关重要。在本研究中,我们考察了等离激元能量膨胀测温法(PEET)作为一种在钨(W)薄片中绘制室温至700°C范围内局部温度的方法的准确性。特别地,我们研究了典型电子透明TEM样品厚度范围(30 nm至70 nm)内,样品厚度对依赖于温度的等离激元能量的影响。用于确定样品局部温度的等离激元能量位移不仅依赖于温度,而且在W中,当样品厚度低于约60 nm时还依赖于厚度。结果凸显了在利用PEET分析局部体等离激元能量以进行温度测量时,考虑样品厚度(尤其是厚度变化)的重要性。然而,在W的情况下,随着样品厚度减小,体等离激元峰的束流展宽(FWHM)增大,这一现象可用于提高存在样品厚度变化的TEM薄片中PEET的精度。

英文摘要:

Advances in analytical scanning transmission electron microscopy (STEM) and microelectronic mechanical systems (MEMS) based microheaters have enabled in-situ materials characterization at the nanometer scale at elevated temperature. In addition to resolving the structural information at elevated temperatures, detailed knowledge of the local temperature distribution inside the sample is essential to reveal thermally induced phenomena and processes. Here, we investigate the accuracy of plasmon energy expansion thermometry (PEET) as a method to map the local temperature in a tungsten (W) lamella in a range between room temperature and 700 degC. In particular, we address the influence of sample thickness in the range of a typical electron-transparent TEM sample (from 30 nm to 70 nm) on the temperature-dependent plasmon energy. The shift in plasmon energy, used to determine the local sample temperature, is not only temperature-dependent, but in case of W also thickness-dependent in sample thicknesses below approximately 60 nm. The results highlight the importance of considering sample thickness (and especially thickness variations) when analyzing the local bulk plasmon energy for temperature measurement using PEET. However, in case of W, an increasing beam broadening (FWHM) of the bulk plasmon peak with decreasing sample thickness can be used to improve the accuracy of PEET in TEM lamellae with varying sample thickness.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑