Low-Rank Adaptation (LoRA) has gained popularity for fine-tuning large foundation models, leveraging low-rank matrices $\mathbf{A}$ and $\mathbf{B}$ to represent weight changes (i.e., $Δ\mathbf{W} = \mathbf{B} \mathbf{A}$). This method reduces trainable parameters and mitigates heavy memory consumption associated with full delta matrices by sequentially multiplying $\mathbf{A}$ and $\mathbf{B}$ with the activation. Despite its success, the intrinsic low-rank characteristic may limit its performance. Although several variants have been proposed to address this issue, they often overlook the crucial computational and memory efficiency brought by LoRA. In this paper, we propose Circular Convolution Adaptation (C$^3$A), which not only achieves high-rank adaptation with enhanced performance but also excels in both computational power and memory utilization. Extensive experiments demonstrate that C$^3$A consistently outperforms LoRA and its variants across various fine-tuning tasks.
Transferable Low-Rank Convolutional Bases for Onboarding Unseen Medical Imaging Modalities
Bangladesh University of Engineering and Technology (BUET)(孟加拉国工程技术大学);Osaka Metropolitan University(大阪都市大学);Chittagong University of Engineering and Technology (CUET)(吉大港工程技术大学);Kochi University of Technology(高知工科大学)
Parameter-efficient Fine-tuning for improved Convolutional Baseline for Brain Tumor Segmentation in Sub-Saharan Africa Adult Glioma Dataset
Nepal Research and Collaboration Center (NRCC)(尼泊尔研究与合作中心);Birendra Multiple Campus, Tribhuvan University(特里布万大学比伦德拉多校区);Institute of Engineering, Purbanchal Campus, Tribhuvan University(特里布万大学普尔班查尔校区工程学院);Bhaktapur Multiple Campus, Tribhuvan University(特里布万大学巴克塔普尔多校区);Gandaki College of Engineering and Science, Pokhara University(博卡拉大学甘达基工程与科学学院);McGill University(麦吉尔大学);Lawson Health Research Institute(劳森健康研究所);Medical Artificial Intelligence Laboratory (MAI Lab), Lagos(拉各斯医学人工智能实验室);University of British Columbia(不列颠哥伦比亚大学);Montreal Neurological Institute, McGill University(麦吉尔大学蒙特利尔神经学研究所)
Convolutional Neural Networks for Medical Image Analysis: Full Training or Fine Tuning?
Arizona State University(亚利桑那州立大学);Mayo Clinic(梅奥诊所)
从头开始训练深度卷积神经网络(CNN)是很困难的,因为它需要大量的标记训练数据和大量的专业知识来确保适当的收敛。一个有希望的替代方案是微调CNN,该CNN已经使用例如大量标记的自然图像进行了预训练。然而,自然图像和医学图像之间的实质性差异可能会反对这种知识转移。在本文中,我们试图回答医学图像分析背景下的以下中心问题:\emph{Can the use of pre-trained deep CNNs with sufficient fine-tuning eliminate the need for training a deep CNN from scratch?}为了解决这个问题,我们考虑了3个专业的4种不同的医学成像应用(放射学、心脏病学和胃肠病学),涉及3种不同成像模式的分类、检测和分割,并研究了从头开始训练的深度CNN的性能如何与以逐层方式微调的预训练CNN进行比较。我们的实验一致表明,(1)使用具有足够微调的预训练的CNN优于或在最坏情况下表现得与从头开始训练的CNN一样好;(2)微调的CNN比从头开始训练的CNN对训练集的大小更鲁棒;(3)浅调或深调都不是特定应用的最佳选择;以及(4)我们的逐层微调方案可以提供一种实用的方法,以根据可用数据的量来达到当前应用的最佳性能。