Tumor Treating Fields (TTFields) is a non-invasive anticancer modality that utilizes alternating electric fields to disrupt cancer cell division and growth. While generally well-tolerated with minimal side effects, traditional TTFields therapy for lung tumors faces challenges due to the influence of respiratory motion. We design a novel closed-loop TTFields strategy for lung tumors by incorporating electrical impedance tomography (EIT) for real-time respiratory phase monitoring and dynamic parameter adjustments. Furthermore, we conduct theoretical analysis to evaluate the performance of the proposed method using the lung motion model. Compared to conventional TTFields settings, we observed that variations in the electrical conductivity of lung during different respiratory phases led to a decrease in the average electric field intensity within lung tumors, transitioning from end-expiratory (1.08 V/cm) to end-inspiratory (0.87 V/cm) phases. Utilizing our proposed closed-Loop TTFields approach at the same dose setting (2400 mA, consistent with the traditional TTFields setting), we can achieve a higher and consistent average electric field strength at the tumor site (1.30 V/cm) across different respiratory stages. Our proposed closed-loop TTFields method has the potential to improved lung tumor therapy by mitigating the impact of respiratory motion.
Magnetic resonance delta radiomics to track radiation response in lung tumors receiving stereotactic MRI-guided radiotherapy
Mass General Brigham(麻省总医院布里格姆医疗系统);Harvard Medical School(哈佛医学院);Dana-Farber Cancer Institute(丹娜-法伯癌症研究所);Harvard T.H. Chan School of Public Health(哈佛大学陈曾熙公共卫生学院);Maastricht University(马斯特里赫特大学)
Real-time volumetric image reconstruction and 3D tumor localization based on a single x-ray projection image for lung cancer radiotherapy
目的:研究一种基于单张X射线投影图像的肺癌放射治疗实时体积图像重建和三维肿瘤定位算法。研究方法:给定一组患者在N个呼吸相位的体积图像作为训练数据,我们在参考相位和其他N-1个相位之间执行可变形图像配准,从而产生N-1个变形矢量场(DVF)。这些DVF可以有效地表示由主成分分析(PCA)获得的一些特征向量和系数。通过改变PCA系数,我们可以生成新的DVF,当将其应用于参考图像时,产生新的体积图像。然后,我们可以通过优化PCA系数来从单个投影图像重建体积图像,使得其计算的投影与测量的投影相匹配。肿瘤的3D位置可以通过在其在参考图像中的位置上应用反转的DVF来导出。我们的算法在图形处理器(GPU)上实现,以实现实时效率。我们使用具有10个呼吸阶段的逼真和动态数学体模生成训练数据。测试数据是对应于一次机架旋转的360个锥形束投影,使用呼吸幅度增加50%的相同体模进行模拟。结果:重建体积图像的平均相对图像强度误差为6.9% ± 2.4%。平均3D肿瘤定位误差为0.8 mm +/- 0.5 mm。在NVIDIA Tesla C1060 GPU卡上,从每个投影重建体积图像的平均计算时间为0.24秒(范围:0.17和0.35秒)。结论:我们已经展示了从单个X射线图像近实时地重建体积图像和在3D中定位肿瘤位置的可行性。
Novel Radiomic Feature for Survival Prediction of Lung Cancer Patients using Low-Dose CBCT Images
Indian Institute of Technology Kharagpur(印度理工学院卡拉格普尔分校);Tata Medical Center(塔塔医学中心);Arden Cancer Centre(雅顿癌症中心);University Hospitals Coventry and Warwickshire(考文垂与沃里克郡大学医院)
Improving image quality of sparse-view lung tumor CT images with U-Net
Technical University of Munich(慕尼黑工业大学);Klinikum rechts der Isar(里斯卡尔医院);Institute for Advanced Study(高等研究院);Munich Institute of Biomedical Engineering(慕尼黑生物医学工程研究所)
Reliability of PET/CT shape and heterogeneity features in functional and morphological components of Non-Small Cell Lung Cancer tumors: a repeatability analysis in a prospective multi-center cohort
INSERM, UMR 1101, LaTIM, University of Brest, IBSAM(法国国家健康与医学研究院,UMR 1101,LaTIM,布雷斯特大学,IBSAM);Academic department of nuclear Medicine, CHU Milétrie(米莱特里大学医院核医学科);Memorial Sloan Kettering Cancer Center(纪念斯隆·凯特琳癌症中心);Mallinckrodt Institute of Radiology and the Siteman Cancer Center, Washington University School of Medicine(华盛顿大学医学院马林克罗特放射学研究所及Siteman癌症中心)