arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2407.04727eess.SP
收藏

用于伪影子空间重建的单通道脑电信号动态嵌入

Dynamical Embedding of Single Channel Electroencephalogram for Artifact Subspace Reconstruction

Doli Hazarika, Vishnu KN, Ramdas Ransing, Cota Navin Gupta

AI总结:

本文提出E-ASR框架,通过动态嵌入将原本依赖多通道的ASR扩展到单通道EEG伪影去除,并在半模拟与真实数据上验证其有效性。

摘要:

本研究提出了一种将伪影子空间重建(Artifact Subspace Reconstruction,ASR)算法应用于单通道脑电(Electroencephalogram,EEG)数据的新颖框架。ASR以其能够自动有效去除EEG信号中眨眼、眼动等多种伪影的能力而闻名。重要的是,它已经在安卓智能手机上实现,但依赖多个通道来进行主成分子空间计算。为克服这一限制,我们将成熟的动态嵌入方法纳入该算法,并将其命名为Embedded-ASR(E-ASR)。在所提出的方法中,首先利用一系列延迟向量从单通道EEG数据构建嵌入矩阵。随后将ASR应用于该嵌入矩阵,并通过消除时滞并拼接嵌入矩阵的各行,重建得到清洁后的单通道EEG。使用CameraEEG应用程序,从四名处于睁眼静息状态的受试者的前额(Fp1和Fp2)电极采集数据。为评估E-ASR算法在含伪影EEG数据集上的有效性,我们采用了相对均方根误差(RRMSE)、相关系数(CC)、平均功率比等性能指标,并估计了使用与不使用E-ASR方法时的眨眼次数。E-ASR能够减少半模拟EEG数据中的伪影,其RRMSE为45.45%,CC为0.91。对于真实EEG数据,针对所有受试者的单个Fp1和Fp2电极,将计数得到的眨眼次数与从CameraEEG视频数据获得的真值进行人工交叉核对。总之,本研究表明E-ASR框架可以去除单通道EEG数据中的伪影。这一有前景的算法可能在基于智能手机的自然环境EEG应用中具有潜力,在这类应用中,最少电极数量是一个关键因素。

英文摘要:

This study introduces a novel framework to apply Artifact Subspace Reconstruction (ASR) algorithm on single-channel Electroencephalogram (EEG) data. ASR, renowned for its automated capability to effectively eliminate various artifacts like eye-blinks and eye movements from EEG signals. Importantly it has been implemented on android smartphones, but relied on multiple channels for principal component subspace calculations. To overcome this limitation, we incorporate the established dynamical embedding approach into the algorithm, naming it Embedded-ASR (E-ASR). In our proposed method, an embedded matrix is first constructed from a single-channel EEG data using series of delay vectors. ASR is then applied to this embedded matrix, and the resulting cleaned single-channel EEG is reconstructed by removing the time lag and concatenating the rows of the embedded matrix. Data was collected from four subjects in resting states with eyes open from pre-frontal (Fp1 and Fp2) electrodes using CameraEEG app. To assess the effectiveness of the E-ASR algorithm on an EEG dataset with artifacts, we employed performance metrics such as relative root mean square error (RRMSE), correlation coefficient (CC), average power ratio as well as estimated the number of eye-blinks with and without the E-ASR approach. E-ASR was able to reduce artifacts from the semi-simulated EEG data, with an RRMSE of 45.45% and a CC of 0.91. For real EEG data, the counted eye-blinks were manually cross-checked with ground truth obtained from CameraEEG video data across all subjects for individual Fp1 and Fp2 electrodes. In conclusion, our study suggests E-ASR framework can remove artifacts from single channel EEG data. This promising algorithm might have potential for smartphone-based natural environment EEG applications, where minimal number of electrodes is a critical factor.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑