LISA Pathfinder 测试质量块磁参数的精密测量

Precision measurements of the magnetic parameters of LISA Pathfinder test masses

M Armano, H Audley, J Baird, P Binetruy, M Born, D Bortoluzzi, E Castelli, A Cavalleri, A Cesarini, A M Cruise, K Danzmann, M De Deus Silva, I Diepholz, G Dixon… 展开作者

M Armano, H Audley, J Baird, P Binetruy, M Born, D Bortoluzzi, E Castelli, A Cavalleri, A Cesarini, A M Cruise, K Danzmann, M De Deus Silva, I Diepholz, G Dixon, R Dolesi, L Ferraioli, V Ferroni, E D Fitzsimons, M Freschi, L Gesa, D Giardini, F Gibert, R Giusteri, C Grimani, J Grzymisch, I Harrison, M S Hartig, G Heinzel, M Hewitson, D Hollington, D Hoyland, M Hueller, H Inchauspé, O Jennrich, P Jetzer, N Karnesis, B Kaune, N Korsakova, C J Killow, L Liu, J A Lobo, J P López-Zaragoza, R Maarschalkerweerd, D Mance, V Martín, J Martino, L Martin-Polo, F Martin-Porqueras, P W McNamara, J Mendes, L Mendes, N Meshksar, M Nofrarias, S Paczkowski, M Perreur-Lloyd, A Petiteau, P Pivato, E Plagnol, J Ramos-Castro, J Reiche, F Rivas, D I Robertson, G Russano, L Sala, D Serrano, J Slutsky, C F Sopuerta, T Sumner, D Texier, J I Thorpe, D Vetrugno, S Vitale, G Wanner, H Ward, P Wass, W J Weber, L Wissel, A Wittchen, P Zweifel

AI总结:

针对未来空间引力波天文台需求,通过LISA Pathfinder运行期间的磁注入实验,高精度测量了测试质量块的剩余磁矩、背景磁场x分量及梯度、低频磁化率,结果与地面估计一致。

摘要:

精确表征 LISA Pathfinder 自由下落测试质量块的磁特性对未来空间引力波天文台具有特殊意义。在毫赫兹以下的低频段,磁力对仪器灵敏度有重要影响。本文报告了在 LISA Pathfinder 整个运行期间进行的磁注入实验。我们展示了这些实验如何实现对仪器磁参数的高精度估计:剩余磁矩的模值为$(0.245\boldsymbol{\text{±}}0.081)\text{ nAm}^2$,测试质量块位置处背景磁场的x分量测量值为$(414\boldsymbol{\text{±}}74)\text{ nT}$,其梯度值为$(-7.4\boldsymbol{\text{±}}2.1)\text{ μT/m}$;最后,我们还测得测试质量块在低频段的磁化率为$(-3.35\boldsymbol{\text{±}}0.15)\times10^{-5}$。所有结果均与地面估计值一致。

英文摘要:

A precise characterization of the magnetic properties of LISA Pathfinder free falling test-masses is of special interest for future gravitational wave observatory in space. Magnetic forces have an important impact on the instrument sensitivity in the low frequency regime below the millihertz. In this paper we report on the magnetic injection experiments performed throughout LISA Pathfinder operations. We show how these experiments allowed a high precision estimate of the instrument magnetic parameters. The remanent magnetic moment was found to have a modulus of $(0.245\pm0.081)\,\rm{nAm}^2$, the x-component of the background magnetic field within the test masses position was measured to be $(414 \pm 74)$ nT and its gradient had a value of $(-7.4\pm 2.1)\,μ$T/m. Finally, we also measured the test mass magnetic susceptibility to be $(-3.35\pm0.15)\times$10$^{-5}$ in the low frequency regime. All results are in agreement with on-ground estimates.