Model predictive control of residential air conditioning could reduce energy costs and greenhouse gas emissions while maintaining or improving occupants' thermal comfort. However, most approaches to predictive air conditioning control either do not model indoor humidity or treat it as constant. This simplification stems from challenges with modeling indoor humidity dynamics, particularly the high-order, nonlinear equations that govern heat and mass transfer between the air conditioner's evaporator coil and the indoor air. This paper develops a machine-learning approach to modeling indoor humidity dynamics that is suitable for real-world deployment at scale. This study then investigates the value of humidity modeling in four field tests of predictive control in an occupied house. The four field tests evaluate two different building models: One with constant humidity and one with time-varying humidity. Each modeling approach is tested in two different predictive controllers: One that focuses on reducing energy costs and one that focuses on constraining electric power below a utility-specified threshold. The two models lead to similar performance for reducing energy costs. Combining the results of this study and a prior heating study of the same house, the estimated year-round energy cost savings were $340-497 or 22-31% (95% confidence intervals); these savings were consistent across both humidity models. However, in the demand response tests, the simplifying assumption of constant humidity led to far more frequent and severe violations of the power constraint. These results suggest that accurate building models are important for nonlinear objectives, such as reducing or constraining peak demand, while for linear objectives such as reducing energy costs or emissions, model accuracy is less important.
Bayesian Learning of Consumer Preferences for Residential Demand Response
V.A. Trapeznikov Institute of Control Sciences of Russian Academy of Sciences(俄罗斯科学院V.A.特拉佩兹尼科夫控制科学研究所);Skolkovo Institute of Science and Technology(斯科尔科沃科学技术研究所);National Research University Higher School of Economics(国家研究型高等经济学院)
Comparative Field Deployment of Reinforcement Learning and Model Predictive Control for Residential HVAC
College of Engineering, Carnegie Mellon University, 5000 Forbes Ave, Pittsburgh, PA 15213, USA;Wilton E. Scott Institute for Energy Innovation, Carnegie Mellon University, 5000 Forbes Ave, Pittsburgh, PA 15213, USA;Center for High Performance Buildings, Purdue University, 177 S Russell St, West Lafayette, IN 47907, USA;Trane Technologies, Residential R\&D Group, 6200 Troup Hwy, Tyler, TX 75707, USA;Bosch Center for Artificial Intelligence
Automated generation of experimentally validated digital twins for desiccant-based low-dew-point air-conditioning systems from declarative topology specifications
Korea Institute of Energy Research(韩国能源研究院);University of Science & Technology(科学技术大学)
Determining optimal thermal energy storage charging temperature for cooling using integrated building and coil modeling
Industrial Science and Technology Research Institute, Inha University(仁荷大学工业科学与技术研究所);Department of Smart City Engineering, Inha University(仁荷大学智慧城市工程学院);Department of Architectural Engineering, INHA University(仁荷大学建筑工程学院)