动态光散射在乳腺癌风险筛查中的频域分析:概念验证
Frequency Domain Analysis of Dynamic Light Scattering in the Breast Cancer Risk Screening: A Proof of Concept
AI总结:
本文提出利用非侵入性和低成本的动态光散射技术检测乳腺组织中的生化变化,通过频域分析验证该方法在早期乳腺异常检测中的可行性。
摘要:
我们提出了一种概念验证方法,利用非侵入性和低成本的技术,通过动态光散射进行场效应检测(FEDSA),以检测乳腺组织中的生化变化。该技术包括一个光源照射组织,然后通过两个探测器收集背向散射光;信号传输至采集系统,随后通过设计的软件计算功率谱。功率谱包含与组织化合物大小相关的频率贡献。这些频率贡献会随着生化变化而改变,且被场效应放大。这表明乳腺中的初始变化并非局部。为了测试FEDSA,进行了两项实验:第一项使用平均尺寸为60-300nm、100-400nm的氧化铝颗粒和悬浮的聚苯乙烯纳米颗粒(315nm)。第二项涉及24名女性,其中17人正常,7人异常;异常情况已通过乳腺X线或超声检测。所有颗粒的功率谱与颗粒尺寸一致。在正常和异常组织中,功率谱在1至160kHz范围内显示形状差异。ROC分析显示分类乳腺组织状况的敏感性(87.5%)和特异性(68.1%)可能良好。统计分析(p<0.05)显示乳腺的两个象限(右内上和左外上)存在显著差异,与之前的乳腺X线和超声诊断一致。这一概念验证为实现和改进FEDSA在乳腺早期异常检测中的应用提供了可能,该方法是一种低成本、不使用电离辐射的技术。
英文摘要:
We present a proof of concept for screening breast cancer risk by detecting biochemical alterations in breast tissue using a noninvasive and low-cost technique that uses dynamic light scattering for field effect detection by spectral analysis (FEDSA). This technique consists of a light source that illuminates the tissue, and the backscattering light by the tissue is acquired by two detectors; next, the signal goes to the acquisition system, and then with the designed software the power spectra are calculated. The power spectra contain the frequency contribution related to the size of tissue compounds. These frequency contributions change with the biochemical alterations that are amplified by the field effect on tissue. This implies that the initial alterations in the breast are not local. To test FEDSA, two experiments were performed: the first was with Alumina particles grouped in average sizes of $60-300nm$, $100 - 400nm$ and polystyrene nanoparticles in suspension ($315nm$). The second was with 24 women, 17 of whom had normal tissue and 7 abnormal; abnormalities were previously detected by mammogram or ultrasound. Power spectra were obtained for all particles, in agreement with the particle size. In the case of normal and abnormal tissues, the power spectra of the tissues show differences in the shape of the spectra in the range of 1 to 160 kHz. ROC analysis suggests a possible good sensitivity (87.5\%) and specificity (68.1\%) in classifying breast tissue conditions. Statistical analysis with $p<0.05$ revealed significant differences in two quadrants of the breast, the upper inner right and the upper outer left, which were consistent with previous diagnoses by mammography and ultrasound. This proof of concept opens the possibility of implementing and improving FEDSA in the detection of early anomalies in the breast as a low-cost technique that does not use ionizing radiation.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。