arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2406.16265physics.bio-phphysics.optics
收藏

无需标记的中红外光热显微镜重新审视细胞内热动力学:荧光纳米热计测量什么?

Label-free mid-infrared photothermal microscopy revisits intracellular thermal dynamics: what do fluorescent nanothermometers measure?

The University of Tokyo(东京大学);RIKEN Center for Advanced Photonics, RIKEN(理化学研究所先进光子学中心)

Keiichiro Toda, Masaharu Takarada, Genki Ishigane, Hiroyuki Shimada, Venkata Ramaiah Badarla, Kohki Okabe, Takuro Ideguchi

AI总结:

研究通过无需标记的中红外光热显微镜揭示细胞内热扩散特性,发现其与水相近,反驳了荧光热计测量的异常慢热传导假说,指出两者测量的物理量本质不同。

摘要:

荧光纳米热计揭示了细胞内温度异质性,确立了单细胞热生物学领域。然而,这些观测引发了所谓的

英文摘要:

Fluorescent nanothermometry has revealed pronounced intracellular temperature heterogeneity, establishing the field of single-cell thermal biology. However, these observations have sparked a controversy known as the "10^5 gap issue", because heat conduction calculations in aqueous environments predict that such large temperature distributions cannot be sustained within cells. Here, we address this issue using label-free mid-infrared photothermal microscopy. This technique quantifies heat-induced temperature changes under local thermal equilibrium (LTE), in accordance with the conventional thermodynamic and statistical-mechanical definition of temperature, by detecting refractive index variations. From transient thermal decay measurements, we determined that intracellular thermal diffusivity corresponds to 93-94% that of water. This result indicates that intracellular heat conduction is essentially water-like and rules out the hypothesis that anomalously slow intracellular heat conduction underlies the 10^5 gap discrepancy. We then directly compared fluorescent nanothermometry with our label-free thermometry. Under seconds-long heating, the label-free method exhibited a rapid temperature response consistent with water-like heat conduction. In contrast, fluorescent nanothermometers showed not only a similarly fast response but also an additional slow variation that was absent in the label-free readout. This slow component cannot be explained by temperature changes defined under LTE, but instead likely reflects slower intracellular processes not governed by conductive heat transfer. These results suggest that the "10^5 gap issue" stems from comparing two fundamentally distinct physical quantities: the LTE-defined temperature and a slowly-varying, long-lived non-conductive signal detected by fluorescent nanothermometers.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑