arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2406.15656eess.IVcs.CV
收藏

用于快速MRI重建的自监督对抗扩散模型

Self-Supervised Adversarial Diffusion Models for Fast MRI Reconstruction

Emory University(埃默里大学)

Mojtaba Safari, Zach Eidex, Shaoyan Pan, Richard L. J. Qiu, Xiaofeng Yang

AI总结:

本文提出自监督一致性引导扩散模型ASSCGD,通过将采样模式划分为两个不相交集合实现无全采样数据的快速MRI重建,在多个加速倍率和分布外数据上优于对比方法。

摘要:

目的:提出一种名为“自适应自监督一致性引导扩散模型(ASSCGD)”的基于自监督深度学习的压缩感知MRI(DL-based CS-MRI)方法,以在无需全采样数据集的情况下加速数据采集。材料与方法:我们使用来自1,376例的fastMRI多线圈脑轴位T2加权(T2-w)数据集和来自318例的单线圈脑定量磁化准备2快速采集梯度回波(MP2RAGE)T1图来训练和测试我们的模型。使用两个分布外(OOD)数据集评估对域偏移的鲁棒性:来自50例的多线圈脑轴位增强后T1加权(T1c)数据集和来自50例患者的轴位T1加权(T1-w)数据集。数据以加速倍率R∈{2x, 4x, 8x}进行回顾性欠采样。ASSCGD将随机采样模式划分为两个不相交的集合,在训练期间确保数据一致性。我们将我们的方法与ReconFormer Transformer和SS-MRI进行比较,使用归一化均方误差(NMSE)、峰值信噪比(PSNR)和结构相似性指数(SSIM)评估性能。统计检验包括单因素方差分析(ANOVA)和多重比较Tukey诚实显著差异(HSD)检验。结果:在多线圈和单线圈数据集上,ASSCGD在R=8x时比对比方法在视觉上更好地保留了精细结构和脑部异常。在多线圈数据集上,它在R∈{4x, 8x}时取得了最低的NMSE,并在所有加速倍率下取得了最高的PSNR和SSIM值。在单线圈数据集上观察到类似趋势,尽管在R∈{2x, 8x}时SSIM值与ReconFormer相当。这些结果进一步通过体素级相关性散点图得到证实。OOD结果显示重建后欠采样图像质量有显著(p<<10^-5)改善。

英文摘要:

Purpose: To propose a self-supervised deep learning-based compressed sensing MRI (DL-based CS-MRI) method named "Adaptive Self-Supervised Consistency Guided Diffusion Model (ASSCGD)" to accelerate data acquisition without requiring fully sampled datasets. Materials and Methods: We used the fastMRI multi-coil brain axial T2-weighted (T2-w) dataset from 1,376 cases and single-coil brain quantitative magnetization prepared 2 rapid acquisition gradient echoes (MP2RAGE) T1 maps from 318 cases to train and test our model. Robustness against domain shift was evaluated using two out-of-distribution (OOD) datasets: multi-coil brain axial postcontrast T1 -weighted (T1c) dataset from 50 cases and axial T1-weighted (T1-w) dataset from 50 patients. Data were retrospectively subsampled at acceleration rates R in {2x, 4x, 8x}. ASSCGD partitions a random sampling pattern into two disjoint sets, ensuring data consistency during training. We compared our method with ReconFormer Transformer and SS-MRI, assessing performance using normalized mean squared error (NMSE), peak signal-to-noise ratio (PSNR), and structural similarity index (SSIM). Statistical tests included one-way analysis of variance (ANOVA) and multi-comparison Tukey's Honesty Significant Difference (HSD) tests. Results: ASSCGD preserved fine structures and brain abnormalities visually better than comparative methods at R = 8x for both multi-coil and single-coil datasets. It achieved the lowest NMSE at R in {4x, 8x}, and the highest PSNR and SSIM values at all acceleration rates for the multi-coil dataset. Similar trends were observed for the single-coil dataset, though SSIM values were comparable to ReconFormer at R in {2x, 8x}. These results were further confirmed by the voxel-wise correlation scatter plots. OOD results showed significant (p << 10^-5 ) improvements in undersampled image quality after reconstruction.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑