arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2405.12014physics.ins-dethep-ex
收藏

DUNE 远探测器 1 的 X-ARAPUCA 光子探测器绝对效率测量

Measurement of the absolute efficiency of the X-ARAPUCA photon detector for the DUNE Far Detector 1

R. Álvarez-Garrote, C. Brizzolari, A. Canto, E. Calvo, C. M. Cattadori, C. Cuesta, A. de la Torre Rojo, I. Gil-Botella, C. Gotti, D. Guffanti, A. A. Machado, S.… 展开作者

R. Álvarez-Garrote, C. Brizzolari, A. Canto, E. Calvo, C. M. Cattadori, C. Cuesta, A. de la Torre Rojo, I. Gil-Botella, C. Gotti, D. Guffanti, A. A. Machado, S. Manthey Corchado, I. Martin, C. Massari, L. Meazza, C. Palomares, L. Pérez-Molina, E. Segreto, F. Terranova, A. Verdugo de Osa, H. Vieira de Souza, D. Warner

AI总结:

本研究评估了 DUNE FD1 X-ARAPUCA 光子探测器的绝对光子探测效率,通过两个实验室独立测量验证,为 NP04 和 DUNE 的分析与重建研究提供关键参数。

摘要:

首个 DUNE 远探测器(FD1)的光子探测系统(PDS)由 6000 个名为 X-ARAPUCA 的光子探测单元组成。探测粒子能量在液氩(LAr)中释放产生的瞬时光脉冲将补充并增强 DUNE 液氩时间投影室(LArTPC)。这将改善非束流事件标记,并使低能下的超新星中微子触发和量热术成为可能。X-ARAPUCA 单元由多个组件组装而成。其光子探测效率(PDE)取决于组装设计、单个组件的等级以及它们的耦合。X-ARAPUCA PDE 是光子探测系统灵敏度的主导参数之一,进而决定了 DUNE 探测银河系内核心坍缩超新星及寻找核子衰变的灵敏度。在本研究中,我们展示了 FD1 X-ARAPUCA 基准设计绝对 PDE 的最终评估结果,该结果在两个实验室通过独立的方法和装置测得。160 个此类 X-ARAPUCA 设备已部署在 CERN 中微子平台的 NP04 设施(1:20 比例的 FD1 原型)中,并将在 2024 年运行。评估的 PDE 值是 NP04 和 DUNE 分析与重建研究中的关键参数。

英文摘要:

The Photon Detection System (PDS) of the first DUNE far detector (FD1) is composed of 6000 photon detection units, named X-ARAPUCA. The detection of the prompt light pulse generated by the particle energy release in liquid argon (LAr) will complement and boost the DUNE Liquid Argon Time Projection Chamber (LArTPC). It will improve the non-beam events tagging and enable at low energies the trigger and the calorimetry of the supernova neutrinos. The X-ARAPUCA unit is an assembly of several components. Its Photon Detection Efficiency (PDE) depends both on the design of the assembly, on the grade of the individual components and finally on their coupling. The X-ARAPUCA PDE is one of the leading parameters for the Photon Detection System sensitivity, that in turn determines the sensitivity of the DUNE for the detection of core-collapse supernova within the galaxy and for nucleon decay searches. In this work we present the final assessment of the absolute PDE of the FD1 X-ARAPUCA baseline design, measured in two laboratories with independent methods and setups. One hundred sixty units of these X-ARAPUCA devices have been deployed in the NP04 facility at the CERN Neutrino Platform, the 1:20 scale FD1 prototype, and will be operated during the year 2024. The assessed value of the PDE is a key parameter both in the NP04 and in the DUNE analysis and reconstruction studies.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑