arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2405.00513q-bio.QM
收藏

用于全小鼠脑动态增强成像的3D MR指纹技术

3D MR Fingerprinting for Dynamic Contrast-Enhanced Imaging of Whole Mouse Brain

Yuran Zhu, Guanhua Wang, Yuning Gu, Walter Zhao, Jiahao Lu, Junqing Zhu, Christina J. MacAskill, Andrew Dupuis, Mark A. Griswold, Dan Ma, Chris A. Flask, Xin Yu

AI总结:

本文提出一种9.4T全脑3D MRF序列,结合基于模型的重建,在4.3分钟时间分辨率下同步定量T1/T2并动态追踪Gd-DTPA转运。

摘要:

定量MRI能够在增强对比剂扫描中直接量化对比剂浓度。然而,传统方法所需的漫长扫描时间不足以动态追踪小鼠脑内对比剂的转运过程。我们开发了一种3D MR指纹(MRF)方法,可在全小鼠脑范围内同时进行T1和T2 mapping,时间分辨率为4.3分钟。我们在一台9.4T临床前MRI扫描仪上设计了一种具有可变采集段长度和磁化准备模块的3D MRF序列。采用基于模型的重建方法以提高MRF采集的准确性和速度。该方法对T1和T2测量的准确性在体外得到验证,而其T1和T2测量的可重复性在体内进行了评估(n=3)。3D MRF序列用于动态追踪全小鼠脑内经脑池内输注的Gd-DTPA的效用得到了证明(n=5)。体模研究证实,在高达48的欠采样因子下,3D MRF仍可进行准确的T1和T2测量。动态对比增强(DCE)MRF扫描实现了192 × 192 × 500 μm³的空间分辨率和4.3分钟的时间分辨率,从而能够分析和比较不同脑区中经脑池内输注的Gd-DTPA浓度和转运动力学的动态变化。该序列还能够在30分钟内实现全小鼠脑高可重复、高分辨率的T1和T2 mapping(192 × 192 × 250 μm³)。我们提出了首个利用3D MRF定量追踪小鼠脑内对比剂转运的动态、多参数方法。

英文摘要:

Quantitative MRI enables direct quantification of contrast agent concentrations in contrast-enhanced scans. However, the lengthy scan times required by conventional methods are inadequate for tracking contrast agent transport dynamically in mouse brain. We developed a 3D MR fingerprinting (MRF) method for simultaneous T1 and T2 mapping across the whole mouse brain with 4.3-min temporal resolution. We designed a 3D MRF sequence with variable acquisition segment lengths and magnetization preparations on a 9.4T preclinical MRI scanner. Model-based reconstruction approaches were employed to improve the accuracy and speed of MRF acquisition. The method's accuracy for T1 and T2 measurements was validated in vitro, while its repeatability of T1 and T2 measurements was evaluated in vivo (n=3). The utility of the 3D MRF sequence for dynamic tracking of intracisternally infused Gd-DTPA in the whole mouse brain was demonstrated (n=5). Phantom studies confirmed accurate T1 and T2 measurements by 3D MRF with an undersampling factor up to 48. Dynamic contrast-enhanced (DCE) MRF scans achieved a spatial resolution of 192 x 192 x 500 um3 and a temporal resolution of 4.3 min, allowing for the analysis and comparison of dynamic changes in concentration and transport kinetics of intracisternally infused Gd-DTPA across brain regions. The sequence also enabled highly repeatable, high-resolution T1 and T2 mapping of the whole mouse brain (192 x 192 x 250 um3) in 30 min. We present the first dynamic and multi-parametric approach for quantitatively tracking contrast agent transport in the mouse brain using 3D MRF.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑