arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2404.15946cs.CVcs.AIeess.IV
收藏

Mammo-CLIP:利用对比语言-图像预训练(CLIP)通过多视图乳腺X线摄影增强乳腺癌诊断

Mammo-CLIP: Leveraging Contrastive Language-Image Pre-training (CLIP) for Enhanced Breast Cancer Diagnosis with Multi-view Mammography

Emory University(埃默里大学);Winship Cancer Institute(温希普癌症研究所);Georgia Institute of Technology(佐治亚理工学院);University of Oklahoma(俄克拉荷马大学)

Xuxin Chen, Yuheng Li, Mingzhe Hu, Ella Salari, Xiaoqian Chen, Richard L. J. Qiu, Bin Zheng, Xiaofeng Yang

AI总结:

研究提出首个多模态框架Mammo-CLIP,通过早期特征融合与即插即用适配器高效微调CLIP,解决多视图乳腺X线图像融合难题,在有限数据下AUC优于现有方法,为下一代基于图文的乳腺癌CAD方案提供新途径。

摘要:

尽管融合来自多视图乳腺X线图像的信息在提高乳腺癌检测准确性方面发挥着重要作用,但开发基于多视图乳腺X线图像的计算机辅助诊断(CAD)方案仍面临挑战,且目前尚无此类CAD方案应用于临床实践。为克服这些挑战,我们研究了一种基于对比语言-图像预训练(CLIP)的新方法,该方法已在各种医学成像任务中引起了广泛关注。通过解决以下挑战:(1) 有效地将单视图CLIP适应于多视图特征融合,以及(2) 在样本和计算资源有限的情况下高效微调这一参数密集型模型,我们提出了Mammo-CLIP,这是首个处理多视图乳腺X线图像及相应简单文本的多模态框架。Mammo-CLIP采用早期特征融合策略,以学习从左右乳腺的CC和MLO视图获取的四张乳腺X线图像中的多视图关系。为了提高学习效率,在CLIP图像和文本编码器中添加了即插即用适配器,用于微调参数并将更新限制在约1%的参数。为了进行框架评估,我们回顾性组装了两个数据集。第一个数据集包含470个恶性和479个良性病例,用于通过5折交叉验证对所提出的Mammo-CLIP进行少样本微调和内部评估。第二个数据集包含60个恶性和294个良性病例,用于测试Mammo-CLIP的泛化能力。研究结果表明,Mammo-CLIP在两个数据集上的AUC(0.841对0.817,0.837对0.807)均优于最先进的跨视图transformer。它还分别以20.3%和14.3%的优势超越了以往两种基于CLIP的方法。本研究突出了应用微调视觉-语言模型开发下一代基于图像-文本的乳腺癌CAD方案的潜力。

英文摘要:

Although fusion of information from multiple views of mammograms plays an important role to increase accuracy of breast cancer detection, developing multi-view mammograms-based computer-aided diagnosis (CAD) schemes still faces challenges and no such CAD schemes have been used in clinical practice. To overcome the challenges, we investigate a new approach based on Contrastive Language-Image Pre-training (CLIP), which has sparked interest across various medical imaging tasks. By solving the challenges in (1) effectively adapting the single-view CLIP for multi-view feature fusion and (2) efficiently fine-tuning this parameter-dense model with limited samples and computational resources, we introduce Mammo-CLIP, the first multi-modal framework to process multi-view mammograms and corresponding simple texts. Mammo-CLIP uses an early feature fusion strategy to learn multi-view relationships in four mammograms acquired from the CC and MLO views of the left and right breasts. To enhance learning efficiency, plug-and-play adapters are added into CLIP image and text encoders for fine-tuning parameters and limiting updates to about 1% of the parameters. For framework evaluation, we assembled two datasets retrospectively. The first dataset, comprising 470 malignant and 479 benign cases, was used for few-shot fine-tuning and internal evaluation of the proposed Mammo-CLIP via 5-fold cross-validation. The second dataset, including 60 malignant and 294 benign cases, was used to test generalizability of Mammo-CLIP. Study results show that Mammo-CLIP outperforms the state-of-art cross-view transformer in AUC (0.841 vs. 0.817, 0.837 vs. 0.807) on both datasets. It also surpasses previous two CLIP-based methods by 20.3% and 14.3%. This study highlights the potential of applying the finetuned vision-language models for developing next-generation, image-text-based CAD schemes of breast cancer.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑