How to Benchmark Vision Foundation Models for Semantic Segmentation?
Eindhoven University of Technology(埃因霍温理工大学)
Tommie Kerssies, Daan de Geus, Gijs Dubbelman
备注:
CVPR 2024 Workshop Proceedings for the Second Workshop on Foundation Models. v2 updates image normalization preprocessing for linear probing with EVA-02, EVA-02-CLIP, SigLIP, DFN (the impact on end-to-end fine-tuning is negligible; no changes made)
Recent vision foundation models (VFMs) have demonstrated proficiency in various tasks but require supervised fine-tuning to perform the task of semantic segmentation effectively. Benchmarking their performance is essential for selecting current models and guiding future model developments for this task. The lack of a standardized benchmark complicates comparisons. Therefore, the primary objective of this paper is to study how VFMs should be benchmarked for semantic segmentation. To do so, various VFMs are fine-tuned under various settings, and the impact of individual settings on the performance ranking and training time is assessed. Based on the results, the recommendation is to fine-tune the ViT-B variants of VFMs with a 16x16 patch size and a linear decoder, as these settings are representative of using a larger model, more advanced decoder and smaller patch size, while reducing training time by more than 13 times. Using multiple datasets for training and evaluation is also recommended, as the performance ranking across datasets and domain shifts varies. Linear probing, a common practice for some VFMs, is not recommended, as it is not representative of end-to-end fine-tuning. The benchmarking setup recommended in this paper enables a performance analysis of VFMs for semantic segmentation. The findings of such an analysis reveal that pretraining with promptable segmentation is not beneficial, whereas masked image modeling (MIM) with abstract representations is crucial, even more important than the type of supervision used. The code for efficiently fine-tuning VFMs for semantic segmentation can be accessed through the project page at: https://tue-mps.github.io/benchmark-vfm-ss/.
Intelligent Communication Mixture-of-Experts Boosted-Medical Image Segmentation Foundation Model
College of Optoelectronics Engineering, Chongqing University, Chongqing, China;Center of Digital Dentistry, Peking University School;Hospital of Stomatology \& NHC Key Laboratory of Digital Stomatology, Beijing, China
Empirical Analysis of a Segmentation Foundation Model in Prostate Imaging
Weill Cornell Medicine(威尔康奈尔医学院);Martinos Center for Biomedical Imaging, Massachusetts General Hospital(麻省总医院马丁诺斯生物医学成像中心);Harvard Medical School(哈佛医学院);Massachusetts Institute of Technology(麻省理工学院);Cornell University(康奈尔大学);Cornell Tech(康奈尔理工学院)
IFSeg: Image-free Semantic Segmentation via Vision-Language Model
Korea Advanced Institute of Science and Technology (KAIST)(韩国科学技术院);Google Research(谷歌研究院);Mohamed bin Zayed University of Artificial Intelligence (MBZUAI)(穆罕默德·本·扎耶德人工智能大学)
Revisiting foundation models for cell instance segmentation
Georg-August-University Göttingen, Institute of Computer Science(哥廷根大学计算机科学学院);CAIMed - Lower Saxony Center for AI & Causal Methods in Medicine, Göttingen(下萨克森人工智能与因果医学方法中心,哥廷根);Cluster of Excellence Multiscale Bioimaging (MBExC), Georg-August-University Göttingen(多尺度生物成像(MBExC)集群,哥廷根大学)
ShapeMamba-EM: Fine-Tuning Foundation Model with Local Shape Descriptors and Mamba Blocks for 3D EM Image Segmentation
National Engineering Research Center of Visual Technology(国家视觉工程研究中心);School of Computer Science, Peking University(北京大学计算机学院);State Key Laboratory of Multimedia Information Processing(多媒体信息处理国家重点实验室);National Biomedical Imaging Center, Peking University(北京大学生物医学成像中心);Peng Cheng Laboratory(鹏城实验室)
Medical SAM3: A Foundation Model for Universal Prompt-Driven Medical Image Segmentation
University of Central Florida, Orlando, USA(佛罗里达大学);University College London, London, UK(伦敦大学学院);University of Illinois Urbana-Champaign, Champaign, USA(伊利诺伊大学厄巴纳-香槟分校);University of Trento, Trento, Italy(特伦托大学);The Hong Kong Polytechnic University, China(香港理工大学);University of Pennsylvania, Philadelphia, USA(宾夕法尼亚大学)
Medical SAM3通过微调SAM3模型,提升医学图像分割的通用提示驱动能力,解决领域偏移和复杂结构推理问题。
Decomposed Vision-Language Alignment for Fine-Grained Open-Vocabulary Segmentation
Aerospace Information Research Institute, Chinese Academy of Sciences(中国科学院航空航天信息研究所);University of Chinese Academy of Sciences(中国科学院大学);Zhejiang University(浙江大学)
An Empirical Study on the Fairness of Foundation Models for Multi-Organ Image Segmentation
Human Phenome Institute, Fudan University(复旦大学人类表型组研究院);School of Computer Science and Engineering, Nanjing University of Science and Technology(南京理工大学计算机科学与工程学院);Ruijin Hospital, Shanghai Jiao Tong University School of Medicine(上海交通大学医学院附属瑞金医院);Brigham and Women’s Hospital, Harvard Medical School(哈佛医学院布莱根妇女医院);School of Computer Science, Fudan University(复旦大学计算机科学技术学院);Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University(复旦大学脑智能科学与技术研究院);MR Business Unit, Philips Healthcare(飞利浦医疗磁共振事业部);Simens Healthineers Ltd., China(西门子医疗中国有限公司);Digital Medical Research Center, School of Basic Medical Sciences, Fudan University(复旦大学基础医学院数字医学研究中心)
VISTA-PATH: An interactive foundation model for pathology image segmentation and quantitative analysis in computational pathology
Department of Pathology and Laboratory Medicine, University of Pennsylvania(病理学与实验室医学系,宾夕法尼亚大学);Department of Electrical and System Engineering, University of Pennsylvania(电气与系统工程系,宾夕法尼亚大学);Department of Biomedical Engineering, Georgia Institute of Technology and Emory University(生物医学工程系,佐治亚理工学院和埃默里大学);NVIDIA Corporation(NVIDIA公司);Department of Biostatistics, Epidemiology and Informatics, University of Pennsylvania(生物统计学、流行病学与信息学系,宾夕法尼亚大学)
Image Segmentation in Foundation Model Era: A Survey
Beijing Institute of Technology(北京理工大学);Shanghai Jiao Tong University(上海交通大学);Zhejiang University(浙江大学);ETH Zurich(苏黎世联邦理工学院);Technical University of Munich(慕尼黑工业大学)