The CG-2 beamline at the High Flux Isotope Reactor (HFIR) exhibits a notable discrepancy between observed count rates and the count rates we would expect based on a Monte-Carlo neutron ray-trace simulation. These simulations consistently predict count rates approximately five times greater than those observed in four separate experimental runs involving different instrument configurations. This discrepancy suggests that certain factors are causing losses in measurements that are not adequately accounted for in the simulation, in particular guide reflectivity or misalignment. To investigate these discrepancies, a high-dimensional simulation parameter approach is applied in order to understand the losses. Region of Interest (ROI) groups along the instrument are assigned to different surfaces of the guide components within the simulation. This allows the parameters of those guide components to be varied as a group to minimize the complexity of the search space. The result is an optimization of simulation parameters using an iterative scheme that aims to minimize the difference between experimentally measured count rates and simulated count rates across all tested collimator combinations. This proposed methodology holds the potential to reveal previously unrecognized sources of intensity loss in the CG-2 beamline at HFIR and improve the accuracy of simulations, leading to enhanced understanding and performance of the beamline for various scientific applications.
Monte-Carlo ray-tracing studies of multiplexed prismatic graphite analyzers for the cold-neutron triple-axis spectrometer at the High Flux Isotope Reactor
Search for Perturbations of Nuclear Decay Rates Induced by Reactor Electron Antineutrinos
我们报告了橡树岭国家实验室高通量同位素反应堆附近进行的实验结果,旨在解决反应堆产生的电子反中微子的通量是否可以改变Mn-54,Na-22和Co-60的弱核相互作用引起的衰变率的问题。这个实验虽然相当灵敏,但在反中微子通量为$3\times 10^{12}$ cm $^{-2}$ s $^{-1}$的情况下,在$β$衰变(或电子俘获)过程中,不能排除$10^4$中少于一个或两个部分的扰动。目前的实验方法适用于广泛的同位素。如果我们能够理解并减少主要的系统不确定性,在未来的实验中提高灵敏度是可能的。
Intensive electron antineutrino source with well defined hard spectrum on the base of nuclear reactor and 8-lithium transfer. The promising experiment for sterile neutrinos search
讨论了未来短基线实验中反中微子源的新概念。来源确保:结果表明,该装置具有以下优点:1)探测器体积约为立方米,每天计数率大于~(1 E +2 - 1 E +3),计数误差小于1%。拟议的来源是基于反应堆活性区附近7 Li的(n,γ)激活以及快速β衰变的8 Li同位素向远程中微子探测器的传输并返回闭环。建议的实验允许检测(电子反中微子,p)的相互作用,具有高精度,并针对搜索无菌中微子与无菌和活性中微子之间的平方质量差~1 eV 2。对(3+1)和(3+2)无菌中微子模型的模拟结果指出了在谱误差范围外寻找电子反中微子消失的空间区域。
CE$ν$NS Search with Cryogenic Sapphire Detectors at MINER: Results from the TRIGA reactor data and Future Sensitivity at HFIR
National Institute of Science Education and Research(印度国家科学教育与研究机构);Sam Houston State University(山姆休斯敦州立大学);University of Toronto(多伦多大学);SNOLAB(斯诺实验室);The University of Texas at Austin(得克萨斯大学奥斯汀分校);University of Minnesota(明尼苏达大学);ARC Centre of Excellence for Dark Matter Particle Physics, School of Physics, The University of Melbourne(墨尔本大学物理学院暗物质粒子物理卓越研究中心);University of South Dakota(南达科他大学)