Mental Stress Detection: Development and Evaluation of a Wearable In-Ear Plethysmography
Hika Barki, Wan-Young Chung
备注:
The paper is being withdrawn because we have identified substantial issues with the data analysis process. To ensure the integrity and accuracy of our findings, we are re-evaluating the data and will resubmit the paper after thorough revisions
Mental stress is a prevalent condition that can have negative impacts on one's health. Early detection and treatment are crucial for preventing related illnesses and maintaining overall wellness. This study presents a new method for identifying mental stress using a wearable biosensor worn in the ear. Data was gathered from 14 participants in a controlled environment using stress-inducing tasks such as memory and math tests. The raw photoplethysmography data was then processed by filtering, segmenting, and transforming it into scalograms using a continuous wavelet transform (CWT) which are based on two different mother wavelets, namely, a generalized Morse wavelet and the analytic Morlet (Gabor) wavelet. The scalograms were then passed through a convolutional neural network classifier, GoogLeNet, to classify the signals as stressed or non-stressed. The method achieved an outstanding result using the generalized Morse wavelet with an accuracy of 91.02% and an F1-score of 90.95%. This method demonstrates promise as a reliable tool for early detection and treatment of mental stress by providing real-time monitoring and allowing for preventive measures to be taken before it becomes a serious issue.
Active noise cancellation on open-ear smart glasses
Department of Electrical and Computer Engineering, Carnegie Mellon University(卡内基梅隆大学电气与计算机工程系);Department of Medical Physics and Acoustics, Carl von Ossietzky Universität Oldenburg(奥尔登堡大学医学物理与声学系);College of Computer Science and Technology, Zhejiang University(浙江大学计算机科学与技术学院)
CoughTrigger: Earbuds IMU Based Cough Detection Activator Using An Energy-efficient Sensitivity-prioritized Time Series Classifier
Northwestern University(西北大学);Samsung Research America(三星美国研究院);Samsung Design Innovation Center(三星设计创新中心)
持续性咳嗽是泌尿系统相关疾病的主要症状。越来越多的研究关注使用可穿戴设备检测咳嗽,尤其是在COVID-19大流行期间。在所使用的所有类型的传感器中,麦克风最广泛地用于检测咳嗽。然而,处理音频信号所需的高功耗阻碍了在电池有限的商用可穿戴产品(例如耳塞)上进行连续的基于音频的咳嗽检测。我们提出了CoughTrigger,它利用耳塞中的低功耗传感器,惯性测量单元(IMU)作为咳嗽检测激活器,以触发用于音频处理和分类的高功率传感器。它能够以最小的电池消耗一直作为备用服务运行,并在从IMU检测到候选咳嗽时触发基于音频的咳嗽检测。此外,IMU的使用带来了改善咳嗽检测特异性的益处。在45名受试者上进行了实验,我们的基于IMU的模型在leave one subject out评价下获得了0.77的AUC得分。我们还验证了其在自由生活数据和设备上实施的有效性。
Detection of Autonomic Dysreflexia in Individuals With Spinal Cord Injury Using Multimodal Wearable Sensors
SCAI-Lab, Department of Health Sciences and Technology (D-HEST), ETH Zurich(SCAI实验室,健康科学与技术系(D-HEST),苏黎世联邦理工学院);School of Computation, Information and Technology, Technical University of Munich(计算、信息与技术学院,慕尼黑技术大学);Swiss Paraplegic Research (SPF)(瑞士瘫痪研究机构(SPF));Institute of Advanced Production Technologies, University of Valladolid(先进生产技术研究所,瓦尔达利德大学);Swiss Paraplegic Centre (SPZ)(瑞士瘫痪中心(SPZ));Balgrist University Hospital(巴尔格里斯大学医院)