arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2407.21433eess.SP
收藏

i-CardiAx:通过长期生命体征监测进行早期脓毒症检测的可穿戴物联网驱动系统

i-CardiAx: Wearable IoT-Driven System for Early Sepsis Detection Through Long-Term Vital Sign Monitoring

Kanika Dheman, Marco Giordano, Cyriac Thomas, Philipp Schilk, Michele Magno

AI总结:

本文提出可穿戴系统i-CardiAx,结合低功耗加速度计与ARM处理器实时监测心率、血压和呼吸率,并部署量化TCN模型,实现长达两周的高效早期脓毒症预测预警。

摘要:

脓毒症是导致早期死亡率、高医疗成本和伤残调整生命年的重要原因。连续心脏监测等数字干预措施有助于发现早期预警信号并促进有效干预。本文介绍了i-CardiAx,这是一种可穿戴传感器,利用低功耗高灵敏度加速度计测量对心血管健康至关重要的生命体征:心率(HR)、血压(BP)和呼吸率(RR)。使用i-CardiAx胸贴从10名健康受试者收集的数据用于开发和评估轻量级生命体征测量算法。算法表现出高性能:RR(-0.11 ± 0.77 breaths/min),HR(0.82 ± 2.85 beats/min)和收缩压BP(-0.08 ± 6.245 mmHg)。这些算法嵌入在支持低功耗蓝牙(BLE)的ARM Cortex-M33处理器中,HR和RR的推理时间为4.2 ms,BP为8.5 ms。此外,还开发了多通道量化时间卷积神经网络(TCN),在开源HiRID数据集上训练,用于利用i-CardiAx数字采集的生命体征检测脓毒症发作。部署在i-CardiAx上的量化TCN预测脓毒症的中位时间为8.2小时,每次推理能耗为1.29 mJ。i-CardiAx可穿戴设备的睡眠功耗为0.152 mW,平均功耗为0.77 mW,使100 mAh电池在每小时进行30次HR、BP和RR连续监测并每30分钟运行一次推理的情况下可持续约两周(432小时)。总之,i-CardiAx提供了一种用于长期心血管监测的节能、高灵敏度方法,为脓毒症和其他危及生命的事件提供预测警报。

英文摘要:

Sepsis is a significant cause of early mortality, high healthcare costs, and disability-adjusted life years. Digital interventions like continuous cardiac monitoring can help detect early warning signs and facilitate effective interventions. This paper introduces i-CardiAx, a wearable sensor utilizing low-power high-sensitivity accelerometers to measure vital signs crucial for cardiovascular health: heart rate (HR), blood pressure (BP), and respiratory rate (RR). Data collected from 10 healthy subjects using the i-CardiAx chest patch were used to develop and evaluate lightweight vital sign measurement algorithms. The algorithms demonstrated high performance: RR (-0.11 $\pm$ 0.77 breaths\min), HR (0.82 $\pm$ 2.85 beats\min), and systolic BP (-0.08 $\pm$ 6.245 mmHg). These algorithms are embedded in an ARM Cortex-M33 processor with Bluetooth Low Energy (BLE) support, achieving inference times of 4.2 ms for HR and RR, and 8.5 ms for BP. Additionally, a multi-channel quantized Temporal Convolutional Neural (TCN) Network, trained on the open-source HiRID dataset, was developed to detect sepsis onset using digitally acquired vital signs from i-CardiAx. The quantized TCN, deployed on i-CardiAx, predicted sepsis with a median time of 8.2 hours and an energy per inference of 1.29 mJ. The i-CardiAx wearable boasts a sleep power of 0.152 mW and an average power consumption of 0.77 mW, enabling a 100 mAh battery to last approximately two weeks (432 hours) with continuous monitoring of HR, BP, and RR at 30 measurements per hour and running inference every 30 minutes. In conclusion, i-CardiAx offers an energy-efficient, high-sensitivity method for long-term cardiovascular monitoring, providing predictive alerts for sepsis and other life-threatening events.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑