arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2404.04427physics.med-pheess.IV
收藏

用于评估可变形图像配准算法的综合肝脏CT标志点对数据集

A comprehensive liver CT landmark pair dataset for evaluating deformable image registration algorithms

Zhendong Zhang, Edward Robert Criscuolo, Yao Hao, Deshan Yang

AI总结:

本文构建了首个基于真实患者图像的大规模肝脏CT可变形图像配准标志点数据集,包含30对图像共2028个标志点,并通过数字体模验证了标注精度,为肝脏DIR算法提供了可靠的定量评估基准。

摘要:

目的:评估可变形图像配准(DIR)算法对于提升算法性能和获得临床认可至关重要。然而,除肺部图像外,目前明显缺乏可靠的DIR基准数据集来评估DIR性能。为填补这一空白,我们旨在推出我们的综合肝脏计算机断层扫描(CT)DIR标志点数据集库。采集与验证方法:从多个公开可用的图像档案库以及作者所在机构(经机构审查委员会批准)获取了三十对肝脏CT图像。图像经过半自动流程处理以生成标志点对:1)对每个病例,在一幅图像上自动分割肝脏血管;2)在血管分叉处自动检测标志点;3)使用可变形图像配准方法在第二幅图像中放置对应标志点;4)应用人工验证以剔除异常值并确认标志点的位置精度。该工作流程平均每对图像产生约68对标志点,30个病例共计2028个标志点。使用数字体模评估了该流程的总体标志点标注精度。数字体模上标志点对目标配准误差(TRE)的均值和标准差估计值分别为0.64毫米和0.40毫米。99%的标志点对TRE低于2毫米。数据格式与使用说明:所有数据在Zenodo上公开可用。使用我们的数据和MATLAB代码的说明可在我们的GitHub页面上找到。潜在应用:本工作生成的标志点数据集是首个在真实患者图像上制备的大规模肝脏CT DIR标志点集合。该数据集可为研究人员提供密集的真值基准集,用于肝脏内DIR算法的定量评估。

英文摘要:

Purpose: Evaluating deformable image registration (DIR) algorithms is vital for enhancing algorithm performance and gaining clinical acceptance. However, there's a notable lack of dependable DIR benchmark datasets for assessing DIR performance except for lung images. To address this gap, we aim to introduce our comprehensive liver computed tomography (CT) DIR landmark dataset library. Acquisition and Validation Methods: Thirty CT liver image pairs were acquired from several publicly available image archives as well as authors' institutions under institutional review board approval. The images were processed with a semi-automatic procedure to generate landmark pairs: 1) for each case, liver vessels were automatically segmented on one image; 2) landmarks were automatically detected at vessel bifurcations; 3) corresponding landmarks in the second image were placed using the deformable image registration method; 4) manual validation was applied to reject outliers and confirm the landmarks' positional accuracy. This workflow resulted in an average of ~68 landmark pairs per image pair, in a total of 2028 landmarks for all 30 cases. The general landmarking accuracy of this procedure was evaluated using digital phantoms. Estimates of the mean and standard deviation of landmark pair target registration errors (TRE) on digital phantoms were 0.64 and 0.40 mm. 99% of landmark pairs had TREs below 2 mm. Data Format and Usage Notes: All data are publicly available at Zenodo. Instructions for using our data and MATLAB code can be found on our GitHub page. Potential Applications: The landmark dataset generated in this work is the first collection of large-scale liver CT DIR landmarks prepared on real patient images. This dataset can provide researchers with a dense set of ground truth benchmarks for the quantitative evaluation of DIR algorithms within the liver.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑