arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2401.07422eess.SP
收藏

基于空时编码RIS的多目标检测与生命体征感知

Multiperson Detection and Vital-Sign Sensing Empowered by Space-Time-Coding RISs

Xinyu Li, Jian Wei You, Ze Gu, Qian Ma, Jingyuan Zhang, Long Chen, Tie Jun Cui

AI总结:

本文提出一种基于空时编码RIS的多目标检测与生命体征监测系统,利用谐波波束扫描检测人员并为每人分配频率正交波束,结合改进VMD算法实现多达四人的呼吸率与心率准确估计。

摘要:

利用无线信号进行被动人体感知因其非接触性和在各种光照条件下的鲁棒性而受到越来越多的关注。然而,当存在多个人体目标时,其反射信号可能在时间、频率和空间域中相互交织,使得分离它们变得困难。为了解决这一问题,本文提出了一种在空时编码(STC)可重构智能超表面(RIS)辅助下的多目标检测与生命体征(即呼吸和心跳)监测新型系统。具体而言,所提系统利用STC RIS产生的谐波波束扫描感兴趣区域(AoI)以进行人体检测。同时,为每个检测到的人员分配频率正交波束,以准确估计其呼吸率(RR)和心率(HR)。此外,为了高效提取呼吸信号和微弱得多的心跳信号,我们提出了一种改进的变分模态分解(VMD)算法,将复杂的反射信号精确分解为数量更少的固有模态函数(IMF)。我们搭建了一个原型系统来验证所提出的多目标检测与生命体征监测系统。实验结果表明,所提系统能够同时监测多达四人的生命体征。使用改进的VMD算法估计的RR和HR误差分别低于1 RPM(每分钟呼吸次数)和5 BPM(每分钟心跳次数)。进一步分析表明,STC RIS所赋予的灵活波束控制机制能够在物理层上减少来自其他无关物体的反射噪声,并提高来自人体胸腔回波的信噪比。

英文摘要:

Passive human sensing using wireless signals has attracted increasing attention due to its superiorities of non-contact and robustness in various lighting conditions. However, when multiple human individuals are present, their reflected signals could be intertwined in the time, frequency and spatial domains, making it challenging to separate them. To address this issue, this paper proposes a novel system for multiperson detection and monitoring of vital signs (i.e., respiration and heartbeat) with the assistance of space-time-coding (STC) reconfigurable intelligent metasurfaces (RISs). Specifically, the proposed system scans the area of interest (AoI) for human detection by using the harmonic beams generated by the STC RIS. Simultaneously, frequencyorthogonal beams are assigned to each detected person for accurate estimation of their respiration rate (RR) and heartbeat rate (HR). Furthermore, to efficiently extract the respiration signal and the much weaker heartbeat signal, we propose an improved variational mode decomposition (VMD) algorithm to accurately decompose the complex reflected signals into a smaller number of intrinsic mode functions (IMFs). We build a prototype to validate the proposed multiperson detection and vital-sign monitoring system. Experimental results demonstrate that the proposed system can simultaneously monitor the vital signs of up to four persons. The errors of RR and HR estimation using the improved VMD algorithm are below 1 RPM (respiration per minute) and 5 BPM (beats per minute), respectively. Further analysis reveals that the flexible beam controlling mechanism empowered by the STC RIS can reduce the noise reflected from other irrelative objects on the physical layer, and improve the signal-to-noise ratio of echoes from the human chest.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑