面向基于CT的身体成分分析的增强肌肉与脂肪分割:一项对比研究

Enhanced Muscle and Fat Segmentation for CT-Based Body Composition Analysis: A Comparative Study

National Institutes of Health (NIH) Clinical Center(美国国立卫生研究院临床中心);Walter Reed National Military Medical Center(沃尔特·里德国家军事医学中心)

Benjamin Hou, Tejas Sudharshan Mathai, Jianfei Liu, Christopher Parnell, Ronald M. Summers

AI总结:

本研究针对CT身体成分分析需求,对比自研内部工具与公开工具TotalSegmentator的肌肉、脂肪分割性能,发现内部工具在皮下脂肪和肌肉分割上更优,二者内脏脂肪分割一致性高,可提升分析准确率。

摘要:

研究目的:从常规腹部CT中获取的身体成分测量结果可为无症状患者及患病患者提供个性化风险评估。具体而言,肌肉与脂肪的衰减值和体积测量值与心血管事件、骨折、死亡等重要临床结局相关。本研究评估了一款内部工具在肌肉与脂肪(皮下脂肪、内脏脂肪)分割任务中的可靠性,并将其与成熟的公开工具TotalSegmentator进行对比。\n研究方法:我们使用公开SAROS数据集的900组CT序列对两款工具进行评估,评估对象为肌肉、皮下脂肪与内脏脂肪。我们采用Dice系数评估皮下脂肪与肌肉分割的准确率。由于缺乏内脏脂肪的真值分割结果,本研究使用Cohen's Kappa系数评估两款工具分割结果的一致性。\n研究结果:我们的内部工具在皮下脂肪分割任务上的Dice系数比TotalSegmentator高3%(83.8 vs. 80.8),在肌肉分割任务上提升了5%(87.6 vs. 83.2)。Wilcoxon符号秩检验显示,两组结果具有统计学差异(p<0.01)。在内脏脂肪分割方面,Cohen's Kappa系数为0.856,表明两款工具的结果几乎完全一致。我们的内部工具在肌肉体积(R²=0.99)、肌肉衰减值(R²=0.93)、皮下脂肪体积(R²=0.99)上均表现出极强的相关性,在皮下脂肪衰减值上呈中等相关性(R²=0.45)。\n研究结论:研究结果表明,我们的内部工具在皮下脂肪与肌肉测量方面的表现优于TotalSegmentator。内脏脂肪的高Cohen's Kappa系数说明两款工具的结果具有可靠的一致性。这些结果证明了我们的工具有望提升身体成分分析的准确率。

英文摘要:

Purpose: Body composition measurements from routine abdominal CT can yield personalized risk assessments for asymptomatic and diseased patients. In particular, attenuation and volume measures of muscle and fat are associated with important clinical outcomes, such as cardiovascular events, fractures, and death. This study evaluates the reliability of an Internal tool for the segmentation of muscle and fat (subcutaneous and visceral) as compared to the well-established public TotalSegmentator tool. Methods: We assessed the tools across 900 CT series from the publicly available SAROS dataset, focusing on muscle, subcutaneous fat, and visceral fat. The Dice score was employed to assess accuracy in subcutaneous fat and muscle segmentation. Due to the lack of ground truth segmentations for visceral fat, Cohen's Kappa was utilized to assess segmentation agreement between the tools. Results: Our Internal tool achieved a 3% higher Dice (83.8 vs. 80.8) for subcutaneous fat and a 5% improvement (87.6 vs. 83.2) for muscle segmentation respectively. A Wilcoxon signed-rank test revealed that our results were statistically different with p<0.01. For visceral fat, the Cohen's kappa score of 0.856 indicated near-perfect agreement between the two tools. Our internal tool also showed very strong correlations for muscle volume (R^2=0.99), muscle attenuation (R^2=0.93), and subcutaneous fat volume (R^2=0.99) with a moderate correlation for subcutaneous fat attenuation (R^2=0.45). Conclusion: Our findings indicated that our Internal tool outperformed TotalSegmentator in measuring subcutaneous fat and muscle. The high Cohen's Kappa score for visceral fat suggests a reliable level of agreement between the two tools. These results demonstrate the potential of our tool in advancing the accuracy of body composition analysis.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑