AI总结:

本研究提出一种深度学习框架,用于在低资源社区助产士使用Android手机采集胎儿多普勒数据时提供实时信号质量评估,实验表明该算法在五折交叉验证中达到97.4%的micro F1分数,有望显著提升数据采集质量。

摘要:

在本研究中,我们提出了一个深度学习框架,旨在与我们先前开发的系统相集成,该系统促进了大规模一维胎儿多普勒数据的采集,旨在提高数据质量。该系统专为低资源社区中的传统原住民助产士量身定制,利用具有成本效益的Android手机来提高记录信号的质量。我们已经证明,多普勒数据可用于识别胎儿生长受限、高血压以及妊娠期间的其他相关问题。然而,信号质量取决于许多因素,包括射频干扰、胎儿位置、母体体型以及助产士对多普勒的使用情况。为了提供即时反馈以便在源头纠正数据,需要一个能够在手机上实时运行的信号质量指标。在本研究中,评估了191个DUS信号的质量,其持续时间主要在5到10分钟之间,并将其分为五类:良好、差、(射频)干扰、说话和静音,分辨率为3.75秒。针对这些录音中的每个3.75秒片段训练了一个深度神经网络,并使用五折交叉验证进行验证。平均实现了micro F1 = 97.4%和macro F1 = 94.2%,其中“良好”质量数据的F1 = 99.2%。这些结果表明,该算法现在将实施在助产士的应用程序中,应能显著提高采集时的数据质量。

英文摘要:

In this study, we present a deep learning framework designed to integrate with our previously developed system that facilitates large-scale 1D fetal Doppler data collection, aiming to enhance data quality. This system, tailored for traditional Indigenous midwives in low-resource communities, leverages a cost-effective Android phone to improve the quality of recorded signals. We have shown that the Doppler data can be used to identify fetal growth restriction, hypertension, and other concerning issues during pregnancy. However, the quality of the signal is dependent on many factors, including radio frequency interference, position of the fetus, maternal body habitus, and usage of the Doppler by the birth attendants. In order to provide instant feedback to allow correction of the data at source, a signal quality metric is required that can run in real-time on the mobile phone. In this study, 191 DUS signals with durations mainly in the range between 5 to 10 minutes were evaluated for quality and classified into five categories: Good, Poor, (Radiofrequency) Interference, Talking, and Silent, at a resolution of 3.75 seconds. A deep neural network was trained on each 3.75-second segment from these recordings and validated using five-fold cross-validation. An average micro F1 = 97.4\% and macro F1 = 94.2\% were achieved, with F1 = 99.2\% for `Good' quality data. These results indicate that the algorithm, which will now be implemented in the midwives' app, should allow a significant increase in the quality of data at the time of capture.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑