arXivDaily arXiv每日学术速递 周一至周五更新
​通知:联邦节假日调休:哥伦布日 / 原住民日(Columbus Day / Indigenous Peoples' Day),今日(13日)无更新。
arXiv 2311.08059eess.IVcs.CV

FS-Net:用于改善微视网膜血管结构提取的全尺度网络与自适应阈值

FS-Net: Full Scale Network and Adaptive Threshold for Improving Extraction of Micro-Retinal Vessel Structures

Skolkovo Institute of Science and Technology (Skoltech)(斯科尔科沃科学技术研究院(斯科尔泰克));Artificial Intelligence Research Institute (AIRI)(人工智能研究院(AIRI));University of Sharjah(沙迦大学);Bian Que AI(扁鹊人工智能);University College London(伦敦大学学院);Research Institute for Medical and Health Sciences(医学与健康科学研究院)

Melaku N. Getahun, Oleg Y. Rogov, Dmitry V. Dylov, Andrey Somov, Ahmed Bouridane, Rifat Hamoudi

AI总结:

本文提出FS-Net,一种基于编码器-解码器架构并融合残差、瓶颈增强、压缩激励等模块的微视网膜血管分割方法,在DRIVE、CHASE-DB1和STARE数据集上取得高精度结果。

摘要:

视网膜血管分割是生物医学图像处理中广泛研究的课题,旨在减轻眼科医生在治疗和检测视网膜疾病时的工作负担。视网膜血管分割面临独特挑战;以往技术往往无法有效分割分支和微血管结构。近期神经网络方法难以平衡局部与全局特性,并且经常遗漏微小的末端血管,阻碍了理想结果的实现。为解决视网膜血管分割中的这些问题,我们提出了一种基于编码器-解码器神经网络架构的综合微血管提取机制。该网络包含残差、编码器增强、瓶颈增强、压缩和激励构建模块。这些组件协同增强特征提取,并提高分割图的预测精度。我们的解决方案已在DRIVE、CHASE-DB1和STARE数据集上进行评估,与先前研究相比取得了具有竞争力的结果。在DRIVE数据集上的AUC和准确率分别为0.9884和0.9702。对于CHASE-DB1数据集,这些分数分别为0.9903和0.9755,对于STARE数据集,分别为0.9916和0.9750。鉴于其准确且稳健的性能,所提出的方法是在现实诊断中心实施并辅助眼科医生的可靠候选方案。

英文摘要:

Retinal vascular segmentation, a widely researched topic in biomedical image processing, aims to reduce the workload of ophthalmologists in treating and detecting retinal disorders. Segmenting retinal vessels presents unique challenges; previous techniques often failed to effectively segment branches and microvascular structures. Recent neural network approaches struggle to balance local and global properties and frequently miss tiny end vessels, hindering the achievement of desired results. To address these issues in retinal vessel segmentation, we propose a comprehensive micro-vessel extraction mechanism based on an encoder-decoder neural network architecture. This network includes residual, encoder booster, bottleneck enhancement, squeeze, and excitation building blocks. These components synergistically enhance feature extraction and improve the prediction accuracy of the segmentation map. Our solution has been evaluated using the DRIVE, CHASE-DB1, and STARE datasets, yielding competitive results compared to previous studies. The AUC and accuracy on the DRIVE dataset are 0.9884 and 0.9702, respectively. For the CHASE-DB1 dataset, these scores are 0.9903 and 0.9755, respectively, and for the STARE dataset, they are 0.9916 and 0.9750. Given its accurate and robust performance, the proposed approach is a solid candidate for being implemented in real-life diagnostic centers and aiding ophthalmologists.