通过拓扑变化改进电网系统,或自组织临界性如何帮助稳定性

Improving power-grid systems via topological changes, or how self-organized criticality can help stability

Géza Ódor, István Papp, Kristóf Benedek, Bálint Hartmann

AI总结:

本研究针对电网级联失效问题,通过识别欧洲电网的桥和弱节点,比较旁路、桥添加等拓扑变化对同步和级联规模的影响,发现布雷斯悖论在同步转变区域附近有效,并验证了级联规模的幂律分布。

摘要:

当电网中一个组件或子系统的失效引发其他组件或子系统的连锁反应,最终导致大面积停电或断电时,就会发生电网级联失效。控制电网级联失效在许多方面都很重要,如经济影响、国家安全、公共安全,甚至波及交通系统等连锁反应。许多人建议在节点层面监控网络,要么控制网络的所有节点,要么控制节点子集。本研究通过两种不同方法识别了加权欧洲电网(来自2016年、2022年)的敏感图元素。社区之间确定了桥,并通过摆动方程的最低局部同步性选择了“弱”节点。在后一种情况下,我们在弱节点处添加与桥数量相同的旁路,并通过动态改进比较其同步性和级联失效行为与纯拓扑变化。结果还与从网络中移除桥(导致类似于孤岛化的情况)以及在随机选定位置添加链路的情况进行了比较。发现旁路对同步的改善最佳,而添加桥时平均级联规模最小。然而,对于非常大或非常小的全局耦合,这些网络变化并无帮助,它们似乎在同步转变区域附近有用,在该区域自组织驱动电网。因此,我们在大陆规模的电网模拟中展示了布雷斯悖论,并揭示了该现象的局限性。我们还确定了级联规模分布,并证明了这些电网在转变点附近的幂律尾部。

英文摘要:

Cascade failures in power grids occur when the failure of one component or subsystem causes a chain reaction of failures in other components or subsystems, ultimately leading to a widespread blackout or outage. Controlling cascade failures on power grids is important for many reasons like economic impact, national security, public safety and even rippled effects like troubling transportation systems. Monitoring the networks on node level has been suggested by many, either controlling all nodes of a network or by subsets. This study identifies sensitive graph elements of the weighted European power-grids (from 2016, 2022) by two different methods. Bridges are determined between communities and "weak" nodes are selected by the lowest local synchronization of the swing equation. In the latter case we add bypasses of the same number as the bridges at weak nodes, and we compare the synchronization, cascade failure behavior by the dynamical improvement with the purely topological changes. The results are also compared if bridges are removed from networks, which results in a case similar to islanding, and with the addition of links at randomly selected places. Bypassing was found to improve synchronization the best, while the average cascade sizes are the lowest with bridge additions. However, for very large or small global couplings these network changes do not help, they seem to be useful near the synchronization transition region, where self-organization drives the power-grid. Thus, we provide a demonstration for the Braess' Paradox on continent-sized power grid simulations and uncover the limitations of this phenomenon. We also determine the cascade size distributions and justify the power-law tails near the transition point on these grids.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑