14.1T下1H-FID-MRSI的降噪技术:Monte-Carlo验证与活体应用
Noise-reduction techniques for 1H-FID-MRSI at 14.1T: Monte-Carlo validation & in vivo application
AI总结:
本研究在14.1T临床前1H-FID-MRSI数据上实现了MP-PCA和LR-TGV两种降噪技术,通过Monte-Carlo模拟和活体实验验证了它们在提高表观SNR和估计精度的同时保持代谢物浓度与区域差异的能力,并强调低浓度代谢物估计需谨慎。
摘要:
质子磁共振波谱成像(1H-MRSI)是一种强大的工具,能够以高分辨率对整个大脑的神经化学图谱进行多维无创映射。1H-MRSI对更高空间分辨率的持续需求,促使人们越来越关注旨在降低噪声方差的基于后处理的去噪方法。本研究旨在实现两种降噪技术:基于Marchenko-Pastur主成分分析(MP-PCA)的去噪和低秩总广义变分(LR-TGV)重建,并测试它们在临床前14.1T快速活体1H-FID-MRSI数据集上的潜力和影响。由于活体代谢物图谱没有已知的真实基准,因此使用Monte-Carlo模拟对两种降噪策略的性能进行了额外评估。结果表明,这两种去噪技术都提高了表观信噪比SNR,同时在活体和Monte-Carlo数据集中保持了每个光谱的噪声特性。两种方法均未显著改变相对代谢物浓度,且在合成和活体数据集中均保留了大脑区域差异。两种方法均观察到代谢物估计精度的提高,但在低浓度代谢物上存在不一致性。我们的研究提供了一个框架,说明如何评估MP-PCA和LR-TGV方法在14.1T临床前1H-FID MRSI数据上的性能。虽然观察到表观SNR和精度的提高,但浓度估计应谨慎处理,特别是对于低浓度代谢物。
英文摘要:
Proton magnetic resonance spectroscopic imaging (1H-MRSI) is a powerful tool that enables the multidimensional non-invasive mapping of the neurochemical profile at high-resolution over the entire brain. The constant demand for higher spatial resolution in 1H-MRSI led to increased interest in post-processing-based denoising methods aimed at reducing noise variance. The aim of the present study was to implement two noise-reduction techniques, the Marchenko-Pastur principal component analysis (MP-PCA) based denoising and the low-rank total generalized variation (LR-TGV) reconstruction, and to test their potential and impact on preclinical 14.1T fast in vivo 1H-FID-MRSI datasets. Since there is no known ground truth for in vivo metabolite maps, additional evaluations of the performance of both noise-reduction strategies were conducted using Monte-Carlo simulations. Results showed that both denoising techniques increased the apparent signal-to-noise ratio SNR while preserving noise properties in each spectrum for both in vivo and Monte-Carlo datasets. Relative metabolite concentrations were not significantly altered by either methods and brain regional differences were preserved in both synthetic and in vivo datasets. Increased precision of metabolite estimates was observed for the two methods, with inconsistencies noted on lower concentrated metabolites. Our study provided a framework on how to evaluate the performance of MP-PCA and LR-TGV methods for preclinical 1H-FID MRSI data at 14.1T. While gains in apparent SNR and precision were observed, concentration estimations ought to be treated with care especially for low-concentrated metabolites.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。