arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2309.08692nucl-ex
收藏

利用固体氘靶在逆运动学中通过$^{12}$Be(d,p)反应研究$^{13}$Be的结构

Structure Studies of $^{13}\text{Be}$ from the $^{12}$Be(d,p) reaction in inverse kinematics on a solid deuteron target

J. Kovoor, K. L. Jones, J. Hooker, M. Vostinar, R. Kanungo, S. D. Pain, M. Alcorta, J. Allen, C. Andreoiu, L. Atar, D. W. Bardayan, S. S. Bhattacharjee, D. Blan… 展开作者

J. Kovoor, K. L. Jones, J. Hooker, M. Vostinar, R. Kanungo, S. D. Pain, M. Alcorta, J. Allen, C. Andreoiu, L. Atar, D. W. Bardayan, S. S. Bhattacharjee, D. Blankstein, C. Burbadge, S. Burcher, W. N. Catford, S. Cha, K. Chae, D. Connolly, B. Davids, N. E. Esker, F. H. Garcia, S. Gillespie, R. Ghimire, A. Gula, G. Hackman, S. Hallam, M. Hellmich, J. Henderson, M. Holl, P. Jassal, S. King, T. Knight, R. Kruecken, A. Lepailleur, J. Liang, L. Morrison, P. D. O'Malley, X. Pereira-Lopez, A. Psaltis, A. Radich, J. Refsgaard, A. C. Shotter, M. Williams, O. Workman

AI总结:

本文利用固体氘靶上的$^{12}$Be(d,p)逆运动学反应并结合贝叶斯分析与GEANT4模拟研究$^{13}$Be低激发结构,结果表明其与较窄$5/2^+$共振宽度的报道更一致。

摘要:

$^{13}$Be的低激发结构数十年来一直是一个谜。尽管已有大量实验和理论研究,仍存在很大的不一致性。$^{13}$Be既是不束缚的,又距离最重的束缚铍核$^{14}$Be仅差一个中子,因此很难通过弱放射性离子束的简单反应或稳定离子束的更复杂反应来研究。本文介绍了利用ISAC-II装置提供的每核子9.5 MeV的$^{12}$Be束,在逆运动学中采用$^{12}$Be(d,p)$^{13}$Be反应进行研究的结果。使用IRIS的固体氘靶,与传统的氘化聚乙烯靶相比,实现了更大的面厚度。利用贝叶斯方法和GEANT4模拟分析了-4.4 MeV以下的Q值谱。对具有相同Q值门的三点角分布,采用$s$波与$p$波、$s$波与$d$波混合或纯$p$波转移进行拟合。还将Q值谱与使用先前四项工作中报道的态能量和宽度获得的GEANT模拟进行了比较。结果发现,我们的结果与揭示宽$5/2^+$共振的工作不相容,但与报道较窄宽度的工作显示出更好的一致性。

英文摘要:

The low-lying structure of $^{13}$Be has remained an enigma for decades. Despite numerous experimental and theoretical studies, large inconsistencies remain. Being both unbound, and one neutron away from $^{14}$Be, the heaviest bound beryllium nucleus, $^{13}$Be is difficult to study through simple reactions with weak radioactive ion beams or more complex reactions with stable-ion beams. Here, we present the results of a study using the $^{12}$Be(d,p)$^{13}$Be reaction in inverse kinematics using a 9.5~MeV per nucleon $^{12}$Be beam from the ISAC-II facility. The solid deuteron target of IRIS was used to achieve an increased areal thickness compared to conventional deuterated polyethylene targets. The Q-value spectrum below -4.4~MeV was analyzed using a Bayesian method with GEANT4 simulations. A three-point angular distribution with the same Q-value gate was fit with a mixture of $s$- and $p$-wave, $s$- and $d$-wave, or pure $p$-wave transfer. The Q-value spectrum was also compared with GEANT simulations obtained using the energies and widths of states reported in four previous works. It was found that our results are incompatible with works that revealed a wide $5/2^+$ resonance but shows better agreement with ones that reported a narrower width.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑