arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2309.08415cs.LGeess.SPphysics.med-ph
收藏

使用带不确定性量化的机器学习建模CRT多阶段决策过程的新方法

A new method of modeling the multi-stage decision-making process of CRT using machine learning with uncertainty quantification

Michigan Technological University(密歇根理工大学);Kennesaw State University(肯尼索州立大学);University of California, Irvine(加利福尼亚大学尔湾分校)

Kristoffer Larsen, Chen Zhao, Joyce Keyak, Qiuying Sha, Diana Paez, Xinwei Zhang, Guang-Uei Hung, Jiangang Zou, Amalia Peix, Weihua Zhou

AI总结:

本研究提出一种基于不确定性量化的多阶段机器学习模型,通过规则逻辑判断是否需额外采集SPECT MPI数据,在不牺牲预测性能的前提下有效减少了对额外数据采集的需求。

摘要:

目的。本研究旨在创建一个多阶段机器学习模型,以预测心力衰竭(HF)患者的心脏再同步化治疗(CRT)反应。如果基线临床变量和心电图(ECG)特征不足,该模型利用不确定性量化来建议额外收集单光子发射计算机断层扫描心肌灌注成像(SPECT MPI)变量。方法。本研究招募了218名接受静息门控SPECT MPI的患者。CRT反应定义为在6+-1个月随访时左心室射血分数(LVEF)增加>5%。通过结合两个集成模型创建了一个多阶段ML模型:Ensemble 1使用临床变量和ECG进行训练;Ensemble 2包括Ensemble 1加上SPECT MPI特征。来自Ensemble 1的不确定性量化允许进行多阶段决策,以确定是否需要为患者采集SPECT数据。将多阶段模型的性能与Ensemble模型1和2进行了比较。结果。CRT反应率为55.5%(n = 121),总体男性占61.0%(n = 133),平均年龄62.0+-11.8,LVEF为27.7+-11.0。多阶段模型表现与Ensemble 2(利用了额外SPECT数据)相似,AUC分别为0.75和0.77,准确率为0.71和0.69,敏感性为0.70和0.72,特异性为0.72和0.65。然而,多阶段模型在所有折中仅需52.7%的患者提供SPECT MPI数据。结论。通过使用源于不确定性量化的基于规则的逻辑,多阶段模型能够在不牺牲性能的情况下减少对额外SPECT MPI数据采集的需求。

英文摘要:

Aims. The purpose of this study is to create a multi-stage machine learning model to predict cardiac resynchronization therapy (CRT) response for heart failure (HF) patients. This model exploits uncertainty quantification to recommend additional collection of single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) variables if baseline clinical variables and features from electrocardiogram (ECG) are not sufficient. Methods. 218 patients who underwent rest-gated SPECT MPI were enrolled in this study. CRT response was defined as an increase in left ventricular ejection fraction (LVEF) > 5% at a 6+-1 month follow-up. A multi-stage ML model was created by combining two ensemble models: Ensemble 1 was trained with clinical variables and ECG; Ensemble 2 included Ensemble 1 plus SPECT MPI features. Uncertainty quantification from Ensemble 1 allowed for multi-stage decision-making to determine if the acquisition of SPECT data for a patient is necessary. The performance of the multi-stage model was compared with that of Ensemble models 1 and 2. Results. The response rate for CRT was 55.5% (n = 121) with overall male gender 61.0% (n = 133), an average age of 62.0+-11.8, and LVEF of 27.7+-11.0. The multi-stage model performed similarly to Ensemble 2 (which utilized the additional SPECT data) with AUC of 0.75 vs. 0.77, accuracy of 0.71 vs. 0.69, sensitivity of 0.70 vs. 0.72, and specificity 0.72 vs. 0.65, respectively. However, the multi-stage model only required SPECT MPI data for 52.7% of the patients across all folds. Conclusions. By using rule-based logic stemming from uncertainty quantification, the multi-stage model was able to reduce the need for additional SPECT MPI data acquisition without sacrificing performance.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑