arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2308.04091cs.CV
收藏

从单模态到多模态:通过深度生成模型改进基于sEMG的模式识别

From Unimodal to Multimodal: improving sEMG-Based Pattern Recognition via deep generative models

School of Design Arts and Media, Nanjing University of Science and Technology(南京理工大学设计艺术与传媒学院)

Wentao Wei, Linyan Ren

AI总结:

本文提出利用深度生成模型从前臂sEMG信号生成虚拟IMU信号,并与sEMG信号共同输入多模态CNN进行手势识别,在六个数据库上验证其准确率显著优于单模态sEMG方法,且接近真实多模态性能,从而在不增加硬件成本的情况下弥合单模态与多模态HGR的差距。

摘要:

目的:与单模态手势识别(HGR)系统相比,多模态HGR系统能够实现更高的识别准确率。然而,获取多模态手势识别数据通常要求用户佩戴额外的传感器,从而增加了硬件成本。方法:本文提出了一种新颖的生成式方法,通过虚拟惯性测量单元(IMU)信号来提升基于表面肌电图(sEMG)的HGR准确率。具体而言,我们首先基于前臂sEMG信号与前臂IMU信号之间的内在相关性训练了一个深度生成模型,以从输入的前臂sEMG信号生成虚拟前臂IMU信号。随后,将sEMG信号和虚拟IMU信号输入多模态卷积神经网络(CNN)模型进行手势识别。结果:我们在六个数据库上进行了评估,包括五个公开数据库和我们自行采集的数据库,该数据库包含28名受试者执行38种手势的数据,同时包含sEMG和IMU数据。结果表明,我们提出的方法显著优于基于sEMG的单模态HGR方法(准确率提升2.15%-13.10%)。此外,在使用虚拟加速度(ACC)信号时,其准确率水平与多模态HGR非常接近。结论:这表明引入由深度生成模型生成的虚拟IMU信号可以显著提高基于sEMG的HGR准确率。意义:所提出的方法是在不增加额外传感器硬件的情况下弥合单模态HGR与多模态HGR之间差距的一次成功尝试,有助于推动生物医学工程领域中自然且成本效益高的肌电接口的进一步发展。

英文摘要:

Objective: Multimodal hand gesture recognition (HGR) systems can achieve higher recognition accuracy compared to unimodal HGR systems. However, acquiring multimodal gesture recognition data typically requires users to wear additional sensors, thereby increasing hardware costs. Methods: This paper proposes a novel generative approach to improve Surface Electromyography (sEMG)-based HGR accuracy via virtual Inertial Measurement Unit (IMU) signals. Specifically, we trained a deep generative model based on the intrinsic correlation between forearm sEMG signals and forearm IMU signals to generate virtual forearm IMU signals from the input forearm sEMG signals at first. Subsequently, the sEMG signals and virtual IMU signals were fed into a multimodal Convolutional Neural Network (CNN) model for gesture recognition. Results: We conducted evaluations on six databases, including five publicly available databases and our collected database comprising 28 subjects performing 38 gestures, containing both sEMG and IMU data. The results show that our proposed approach significantly outperforms the sEMG-based unimodal HGR approach (with increases of 2.15%-13.10%). Moreover, it achieves accuracy levels closely matching those of multimodal HGR when using virtual Acceleration (ACC) signals. Conclusion: It demonstrates that incorporating virtual IMU signals, generated by deep generative models, can significantly improve the accuracy of sEMG-based HGR. Significance: The proposed approach represents a successful attempt to bridge the gap between unimodal HGR and multimodal HGR without additional sensor hardware, which can help to promote further development of natural and cost-effective myoelectric interfaces in the biomedical engineering field.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑