关于用DSSD探测器测量的共享信号

On the sharing signals measured with DSSD detector

Yu. S. Tsyganov, D. Ibadullayev

AI总结:

本文研究大面积DSSD探测器中的电荷共享信号,指出条间距和阈值是主导因素,并简要分析了其他影响参数。

摘要:

本文报告了用大面积DSSD探测器测量的共享信号的合理性质。该探测器由英国Micron Semiconductor公司制造,并用于安装在联合核研究所(JINR)核反应实验室(FLNR)DC-280超强回旋加速器上的DGFRS-2装置。文中还给出了其他装置的一些结果。我们认为,条间距值和阈值在电荷共享过程中起主导作用。文中还简要考虑了受该过程影响的其他一些参数,但有时以半定量形式给出。

英文摘要:

In this paper we report on the reasonable nature of sharing signals measured with large area DSSD detectors. This detector manufactured by Micron Semiconductor (UK) and in use at the DGFRS-2 setup installed at DC-280 ultra intense cyclotron of FLNR, JINR. Some results from other setups are presented. We believe that pitch value as well as threshold value play dominant role in the charge sharing process. Some other parameters influenced by that process are considered in brief too, but sometimes in semi-quantity form.