GenerateCT:基于文本条件的3D胸部CT体数据生成

GenerateCT: Text-Conditional Generation of 3D Chest CT Volumes

Imperial College London(帝国理工学院);University of Pennsylvania(宾夕法尼亚大学);Stanford University(斯坦福大学)
Ibrahim Ethem Hamamci, Sezgin Er, Anjany Sekuboyina, Enis Simsar, Alperen Tezcan, Ayse Gulnihan Simsek, Sevval Nil Esirgun, Furkan Almas, Irem Dogan, Muhammed F… 展开作者

Ibrahim Ethem Hamamci, Sezgin Er, Anjany Sekuboyina, Enis Simsar, Alperen Tezcan, Ayse Gulnihan Simsek, Sevval Nil Esirgun, Furkan Almas, Irem Dogan, Muhammed Furkan Dasdelen, Chinmay Prabhakar, Hadrien Reynaud, Sarthak Pati, Christian Bluethgen, Mehmet Kemal Ozdemir, Bjoern Menze

AI总结:

本研究提出首个基于自由文本提示生成3D胸部CT的GenerateCT方法,通过多组件架构实现文本与影像对齐,实验证明其能有效提升多异常分类性能,还可扩展合成数据规模且生成结果符合临床文本要求。

摘要:

GenerateCT是首个依托自由形式医学文本提示生成3D医学影像的方法,它整合了一个文本编码器与三大核心组件:用于编码3D CT体数据的新型因果视觉Transformer、用于对齐CT与文本token的文本-图像Transformer,以及文本条件超分辨率扩散模型。由于3D医学影像领域暂无直接可比的方法,我们将GenerateCT与前沿方法进行基准测试,证明其在所有关键指标上均表现更优。\n重要的是,我们在多异常分类任务中评估了GenerateCT的临床应用价值。首先,我们在真实数据集上训练多异常分类器,建立了基线。为进一步评估模型对外部数据的泛化能力,以及在零样本场景下处理未见过的提示的性能,我们使用外部数据集训练分类器,设置了额外基准。我们开展了两项实验,通过GenerateCT为每组合成等量的体数据,使训练数据集规模翻倍。第一项实验表明,在真实与生成体数据上联合训练分类器时,AP分数提升了11%;第二项实验显示,基于未见过的提示,在真实与生成体数据上共同训练时,AP分数提升了7%。\n此外,GenerateCT支持将合成训练数据集扩展至任意规模。作为示例,我们生成了10万份3D CT,是真实数据集数量的5倍,并仅用这些合成CT训练分类器。令人印象深刻的是,该分类器的性能超过了在所有可用真实数据上训练的分类器,幅度达8%。最后,领域专家对生成的体数据进行了评估,确认其与文本提示高度对齐。可通过https://github.com/ibrahimethemhamamci/GenerateCT获取我们的代码、模型权重、训练数据及生成数据。

英文摘要:

GenerateCT, the first approach to generating 3D medical imaging conditioned on free-form medical text prompts, incorporates a text encoder and three key components: a novel causal vision transformer for encoding 3D CT volumes, a text-image transformer for aligning CT and text tokens, and a text-conditional super-resolution diffusion model. Without directly comparable methods in 3D medical imaging, we benchmarked GenerateCT against cutting-edge methods, demonstrating its superiority across all key metrics. Importantly, we evaluated GenerateCT's clinical applications in a multi-abnormality classification task. First, we established a baseline by training a multi-abnormality classifier on our real dataset. To further assess the model's generalization to external data and performance with unseen prompts in a zero-shot scenario, we employed an external set to train the classifier, setting an additional benchmark. We conducted two experiments in which we doubled the training datasets by synthesizing an equal number of volumes for each set using GenerateCT. The first experiment demonstrated an 11% improvement in the AP score when training the classifier jointly on real and generated volumes. The second experiment showed a 7% improvement when training on both real and generated volumes based on unseen prompts. Moreover, GenerateCT enables the scaling of synthetic training datasets to arbitrary sizes. As an example, we generated 100,000 3D CTs, fivefold the number in our real set, and trained the classifier exclusively on these synthetic CTs. Impressively, this classifier surpassed the performance of the one trained on all available real data by a margin of 8%. Last, domain experts evaluated the generated volumes, confirming a high degree of alignment with the text prompt. Access our code, model weights, training data, and generated data at https://github.com/ibrahimethemhamamci/GenerateCT