arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2601.22696cs.CVcs.LG
收藏

Bi-MCQ:重新表述视觉-语言对齐以理解否定

Bi-MCQ: Reformulating Vision-Language Alignment for Negation Understanding

Department of Electrical and Computer Engineering, Inha University, Republic of Korea(电气与计算机工程系,印哈大学,大韩民国);College of Medicine, Inha University, Republic of Korea(医学学院,印哈大学,大韩民国)

Tae Hun Kim, Hyun Gyu Lee

AI总结:

Bi-MCQ通过重新表述视觉-语言对齐为条件语义比较,提升医学VLM对否定理解的性能。

摘要:

最近的视觉-语言模型(VLMs)通过大规模图像-文本预训练实现了强大的零样本性能,并已在医学图像分析中被广泛应用。然而,现有的VLMs在理解否定的临床陈述方面仍然明显薄弱,这主要是因为对比对齐目标将否定视为一种次要的语言变化,而不是意义翻转的操作符。在多标签设置中,基于提示的InfoNCE微调进一步强化了容易的正图像-提示对齐,限制了疾病缺失的有效学习。为了克服这些限制,我们将视觉-语言对齐重新表述为一个条件语义比较问题,这通过双向多选学习框架(Bi-MCQ)实现。通过联合训练图像到文本和文本到图像的多选任务,使用肯定、否定和混合提示,我们的方法将微调实现为条件语义比较,而不是全局相似性最大化。我们进一步引入方向特定的交叉注意力融合模块,以解决双向推理所需的不对称线索,并减少对齐干扰。在ChestXray14、Open-I、CheXpert和PadChest上的实验表明,Bi-MCQ在零样本性能方面比最先进的CARZero模型提高了多达0.47 AUC,同时在正负结合(PNC)评估上实现了高达0.08的绝对增益。此外,Bi-MCQ将肯定-否定AUC差距平均减少了0.12,表明目标重新表述可以显著增强医学VLMs中的否定理解。

英文摘要:

Recent vision-language models (VLMs) achieve strong zero-shot performance via large-scale image-text pretraining and have been widely adopted in medical image analysis. However, existing VLMs remain notably weak at understanding negated clinical statements, largely due to contrastive alignment objectives that treat negation as a minor linguistic variation rather than a meaning-inverting operator. In multi-label settings, prompt-based InfoNCE fine-tuning further reinforces easy-positive image-prompt alignments, limiting effective learning of disease absence. To overcome these limitations, we reformulate vision-language alignment as a conditional semantic comparison problem, which is instantiated through a bi-directional multiple-choice learning framework(Bi-MCQ). By jointly training Image-to-Text and Text-to-Image MCQ tasks with affirmative, negative, and mixed prompts, our method implements fine-tuning as conditional semantic comparison instead of global similarity maximization. We further introduce direction-specific Cross-Attention fusion modules to address asymmetric cues required by bi-directional reasoning and reduce alignment interference. Experiments on ChestXray14, Open-I, CheXpert, and PadChest show that Bi-MCQ improves negation understanding by up to 0.47 AUC over the zero-shot performance of the state-of-the-art CARZero model, while achieving up to a 0.08 absolute gain on positive-negative combined (PNC) evaluation. Additionally, Bi-MCQ reduces the affirmative-negative AUC gap by an average of 0.12 compared to InfoNCE-based fine-tuning, demonstrating that objective reformulation can substantially enhance negation understanding in medical VLMs.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑