arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2303.09340eess.IVcs.CVcs.LGphysics.med-ph
收藏

通过基于深度卷积神经网络的伪影减少改进稀疏视图计算机断层扫描中的自动出血检测

Improving Automated Hemorrhage Detection in Sparse-view Computed Tomography via Deep Convolutional Neural Network based Artifact Reduction

Johannes Thalhammer, Manuel Schultheiss, Tina Dorosti, Tobias Lasser, Franz Pfeiffer, Daniela Pfeiffer, Florian Schaff

AI总结:

本文提出用U-Net对稀疏视图颅脑CT进行伪影减少后处理,在仅512个视图下即可保持与4096个视图相当的自动出血检测性能,从而在显著降低辐射剂量的同时保障诊断准确性。

摘要:

这是一份预印本。最新版本已发表于:https://pubs.rsna.org/doi/10.1148/ryai.230275。目的:稀疏视图计算机断层扫描(CT)通过减少采集的总视图数量来有效降低辐射剂量,但代价是图像质量下降,进而可能影响疾病检测能力。我们探索基于深度学习的稀疏视图颅脑CT扫描伪影减少方法及其对自动出血检测的影响。方法:我们在来自一个公开数据集的3000名患者的模拟稀疏视图颅脑CT扫描上训练了一个用于伪影减少的U-Net,这些扫描以不同的子采样水平进行重建。此外,我们在来自17,545名患者的全采样CT数据上训练了一个用于自动出血检测的卷积神经网络。我们使用受试者工作特征曲线下面积(AUC-ROCs)及其相应的95%置信区间(CIs)和DeLong检验以及混淆矩阵来评估分类性能。将U-Net的性能与基于全变分(TV)的解析方法进行了比较。结果:在图像质量和自动出血诊断方面,U-Net的表现优于未处理图像和TV处理图像。采用U-Net后处理,视图数量可以从4096个视图(AUC-ROC:0.974;95% CI:0.972-0.976)减少到512个视图(0.973;0.971-0.975),出血检测性能下降极小(P<.001),减少到256个视图(0.967;0.964-0.969)时性能略有下降(P<.001)。结论:结果表明,基于U-Net的伪影减少显著增强了稀疏视图颅脑CT中的自动出血检测。我们的发现强调,适当的后处理对于在最小化辐射剂量的同时实现最佳图像质量和诊断准确性至关重要。

英文摘要:

This is a preprint. The latest version has been published here: https://pubs.rsna.org/doi/10.1148/ryai.230275 Purpose: Sparse-view computed tomography (CT) is an effective way to reduce dose by lowering the total number of views acquired, albeit at the expense of image quality, which, in turn, can impact the ability to detect diseases. We explore deep learning-based artifact reduction in sparse-view cranial CT scans and its impact on automated hemorrhage detection. Methods: We trained a U-Net for artefact reduction on simulated sparse-view cranial CT scans from 3000 patients obtained from a public dataset and reconstructed with varying levels of sub-sampling. Additionally, we trained a convolutional neural network on fully sampled CT data from 17,545 patients for automated hemorrhage detection. We evaluated the classification performance using the area under the receiver operator characteristic curves (AUC-ROCs) with corresponding 95% confidence intervals (CIs) and the DeLong test, along with confusion matrices. The performance of the U-Net was compared to an analytical approach based on total variation (TV). Results: The U-Net performed superior compared to unprocessed and TV-processed images with respect to image quality and automated hemorrhage diagnosis. With U-Net post-processing, the number of views can be reduced from 4096 (AUC-ROC: 0.974; 95% CI: 0.972-0.976) views to 512 views (0.973; 0.971-0.975) with minimal decrease in hemorrhage detection (P<.001) and to 256 views (0.967; 0.964-0.969) with a slight performance decrease (P<.001). Conclusion: The results suggest that U-Net based artifact reduction substantially enhances automated hemorrhage detection in sparse-view cranial CTs. Our findings highlight that appropriate post-processing is crucial for optimal image quality and diagnostic accuracy while minimizing radiation dose.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑