arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2301.11298physics.plasm-ph
收藏

研究分子电荷交换率对脱附态SOLPS-ITER模拟的影响

Investigating the impact of the molecular charge-exchange rate on detached SOLPS-ITER simulations

Kevin Verhaegh, Aelwyn C Williams, David Moulton, Bruce Lipschultz, Basil P. Duval, Olivier Fevrier, Alexandre Fil, Nick Osborne, Holger Reimerdes, Christian Theiler

AI总结:

本研究针对SOLPS-ITER模拟与TCV氘等离子体实验在氢系发射上的分歧,通过禁用离子同位素质量重新标度调整分子电荷交换率,发现模拟结果与实验的多方面一致性显著提升。

摘要:

等离子体-分子相互作用会产生分子离子,这些分子离子与等离子体发生反应,并通过分子活化复合(MAR)过程促进脱附——该过程会降低离子靶通量,同时还会通过分子活化解离(MAD)过程发挥作用,这两种过程都会产生激发态原子。在脱附态的TCV、JET和MAST-U氘等离子体实验中,已检测到这些原子产生的氢系发射谱。然而,TCV的实验结果与针对氘的SOLPS-ITER模拟结果存在分歧:模拟显示分子离子($D_2^+$)密度不足以产生显著的氢系发射,这一差异被归因于氘的分子电荷交换率($D_2 + D^+ \rightarrow D_2^+ + D$)被低估——该速率是通过按同位素质量重新标度氢的速率得到的。\n在本研究中,我们开展了新的SOLPS-ITER模拟,分别采用默认速率设置和禁用离子同位素质量重新标度的修正速率设置。修正设置使$D_2^+$含量提升了100倍以上。禁用离子同位素质量重新标度后:1)由于MAR过程的纳入,总离子汇增加了一倍以上;2)额外的MAR过程导致离子靶通量在脱附过程中出现滚降;3)偏滤器内的总$Dα$发射在深度脱附阶段增加了约4倍;4)偏滤器内的中性原子密度因MAD过程翻倍,导致中性压力提升50%;5)总氢系功率损失因MAD过程最高增加60%。这些差异使得实验与模拟在光谱测量、离子源/汇推断以及离子靶通量滚降的出现情况方面的一致性得到了提升。

英文摘要:

Plasma-molecular interactions generate molecular ions which react with the plasma and contribute to detachment through molecular activated recombination (MAR), reducing the ion target flux, and molecular activated dissociation (MAD), both of which create excited atoms. Hydrogenic emission from these atoms have been detected experimentally in detached TCV, JET and MAST-U deuterium plasmas. The TCV findings, however, were in disagreement with SOLPS-ITER simulations for deuterium indicating a molecular ion density ($D_2^+$) that was insufficient to lead to significant hydrogenic emission, which was attributed to underestimates of the molecular charge exchange rate ($D_2 + D^+ \rightarrow D_2^+ + D$) for deuterium (obtained by rescaling the hydrogen rates by their isotope mass). In this work, we have performed new SOLPS-ITER simulations with the default rate setup and a modified rate setup where ion isotope mass rescaling was disabled. This increased the $D_2^+$ content by $> \times 100$. By disabling ion isotope mass rescaling: 1) the total ion sinks are more than doubled due to the inclusion of MAR; 2) the additional MAR causes the ion target flux to roll-over during detachment; 3) the total $Dα$ emission in the divertor increases during deep detachment by roughly a factor four; 4) the neutral atom density in the divertor is doubled due to MAD, leading to a 50\% increase in neutral pressure; 5) total hydrogenic power loss is increased by up to 60\% due to MAD. These differences result in an improved agreement between the experiment and the simulations in terms of spectroscopic measurements, ion source/sink inferences and the occurrence of an ion target flux roll-over.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑