arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2301.06244cs.ROcs.SYeess.SY
收藏

下肢外骨骼的触觉透明度与交互力控制

Haptic Transparency and Interaction Force Control for a Lower-Limb Exoskeleton

Northwestern University(西北大学);Shirley Ryan AbilityLab(雪莉·瑞安能力实验室)

Emek Barış Küçüktabak, Yue Wen, Sangjoon J. Kim, Matthew Short, Daniel Ludvig, Levi Hargrove, Eric Perreault, Kevin Lynch, Jose Pons

AI总结:

本文提出全身外骨骼闭环补偿(WECC)方法,利用全身动力学与关节扭矩测量计算步态周期内的交互扭矩,并通过约束优化实现闭环跟踪,在实验中显著优于简化模型控制器,实现了下肢外骨骼的高触觉透明度。

摘要:

控制人与外骨骼之间的交互力对于提供透明度或调节辅助与阻力水平至关重要。然而,对于为不受限的地面行走而设计的下肢外骨骼,如何控制其交互力仍是一个未解决的问题。对于这类外骨骼,在用户与外骨骼之间的每个接触处安装力/扭矩传感器以进行直接力测量具有挑战性。此外,补偿外骨骼的全身重力和动力学力非常重要,尤其是对于重型下肢外骨骼。以往的工作要么通过将腿部视为独立的双摆来简化动力学模型,要么没有利用交互力反馈来闭环控制。所提出的全身外骨骼闭环补偿(WECC)方法通过在髋膝外骨骼上使用全身动力学和关节扭矩测量来计算完整步态周期内的交互扭矩。此外,它采用约束优化方案在闭环中跟踪期望的交互扭矩,同时考虑物理和安全约束。我们在三名受试者上评估了WECC控制的触觉透明度和动态交互扭矩跟踪性能。我们还将WECC与基于简化动力学模型的控制器以及外骨骼的被动版本进行了性能比较。在零和非零期望交互扭矩条件下,WECC控制器在整个步态周期内均产生持续较低的绝对交互扭矩误差。相比之下,简化控制器在支撑相期间跟踪期望交互扭矩的性能较差。

英文摘要:

Controlling the interaction forces between a human and an exoskeleton is crucial for providing transparency or adjusting assistance or resistance levels. However, it is an open problem to control the interaction forces of lower-limb exoskeletons designed for unrestricted overground walking. For these types of exoskeletons, it is challenging to implement force/torque sensors at every contact between the user and the exoskeleton for direct force measurement. Moreover, it is important to compensate for the exoskeleton's whole-body gravitational and dynamical forces, especially for heavy lower-limb exoskeletons. Previous works either simplified the dynamic model by treating the legs as independent double pendulums, or they did not close the loop with interaction force feedback. The proposed whole-exoskeleton closed-loop compensation (WECC) method calculates the interaction torques during the complete gait cycle by using whole-body dynamics and joint torque measurements on a hip-knee exoskeleton. Furthermore, it uses a constrained optimization scheme to track desired interaction torques in a closed loop while considering physical and safety constraints. We evaluated the haptic transparency and dynamic interaction torque tracking of WECC control on three subjects. We also compared the performance of WECC with a controller based on a simplified dynamic model and a passive version of the exoskeleton. The WECC controller results in a consistently low absolute interaction torque error during the whole gait cycle for both zero and nonzero desired interaction torques. In contrast, the simplified controller yields poor performance in tracking desired interaction torques during the stance phase.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑