arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2301.04708nucl-exphysics.ins-det
收藏

双光子交换--TPEX

Two-Photon EXchange -- TPEX

R. Alarcon, R. Beck, J. C. Bernauer, M. Broering, E. Cline, B. Dongwi, I. Fernando, M. Finger, M. Finger, I. Friščić, T. Gautam, D. K. Hasell, O. Hen, J. Holmes… 展开作者

R. Alarcon, R. Beck, J. C. Bernauer, M. Broering, E. Cline, B. Dongwi, I. Fernando, M. Finger, M. Finger, I. Friščić, T. Gautam, D. K. Hasell, O. Hen, J. Holmes, T. Horn, E. Ihloff, R. Johnston, J. Kelsey, M. Kohl, T. Kutz, I. Lavrukhin, S. Lee, W. Lorenzon, F. Maas, H. Merkel, R. G. Milner, P. Moran, J. Nazeer, T. Patel, M. Rathnayake, R. Raymond, R. P. Redwine, A. Schmidt, U. Schneekloth, D. Sokhan, M. Suresh, C. Vidal

摘要:

我们提出了一个新的测量的比例的正电子-质子,电子-质子,弹性散射在DESY确定的贡献以外的单光子交换,这是必不可少的QED描述的最基本的过程在强子物理。一个20 cm长的液氢靶与DESY同步加速器的引出束一起产生的平均亮度为$2.12\times10^{35}$~cm $^{-2}\cdot$ s $^{-1}\cdot$ sr $^{-1}$(是OLYMPUS亮度的$\sim200$倍)。2GeV的试运行和3GeV的测量将提供高达$Q^2=4.6$~(GeV/$c$)$^2$(两倍于目前测量范围)的新数据。钨酸铅量热计将用于探测$30^\circ$、$50^\circ$、$70^\circ$、$90^\circ$和$110^\circ$极角处的散射轻子。测量可以被调度为不干扰PETRA的操作。我们目前的速率估计和模拟计划的测量,包括背景考虑。在2019年,2021年和2022年使用原型钨酸铅热量计在DESY试验束设施进行了初步测量,以检查蒙特卡罗模拟和热量计的性能。这些测试还研究了不同的读出方案(触发和流式)。可以进行各种升级以缩短运行时间,并提供更高的光束能量,从而获得更大的$Q^2$范围。

英文摘要:

We propose a new measurement of the ratio of positron-proton to electron-proton, elastic scattering at DESY to determine the contributions beyond single-photon exchange, which are essential to the QED description of the most fundamental process in hadronic physics. A 20~cm long liquid hydrogen target together with the extracted beam from the DESY synchrotron would yield an average luminosity of $2.12\times10^{35}$~cm$^{-2}\cdot$s$^{-1}\cdot$sr$^{-1}$ ($\sim200$ times the luminosity achieved by OLYMPUS). A commissioning run at 2 GeV followed by measurements at 3 GeV would provide new data up to $Q^2=4.6$~(GeV/$c$)$^2$ (twice the range of current measurements). Lead tungstate calorimeters would be used to detect the scattered leptons at polar angles of $30^\circ$, $50^\circ$, $70^\circ$, $90^\circ$, and $110^\circ$. The measurements could be scheduled to not interfere with the operation of PETRA. We present rate estimates and simulations for the planned measurements including background considerations. Initial measurements at the DESY test beam facility using prototype lead tungstate calorimeters in 2019, 2021, and 2022 were made to check the Monte Carlo simulations and the performance of the calorimeters. These tests also investigated different readout schemes (triggered and streaming). Various upgrades are possible to shorten the running time and to make higher beam energies and thus greater $Q^2$ ranges accessible.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑