大间距AC-LGAD在不同N+注入剂量下的性能

The performance of large-pitch AC-LGAD with different N+ dose

Mengzhao Li, Weiyi Sun, Zhijun Liang, Mei Zhao, Xiaoxu Zhang, Yuan Feng, Yunyun Fan, Tianya Wu, Wei Wang, Xuan Yang, Bo Liu, Shuqi Li, Chengjun Yu, Xinhui Huang… 展开作者

Mengzhao Li, Weiyi Sun, Zhijun Liang, Mei Zhao, Xiaoxu Zhang, Yuan Feng, Yunyun Fan, Tianya Wu, Wei Wang, Xuan Yang, Bo Liu, Shuqi Li, Chengjun Yu, Xinhui Huang, Yuekun Heng, Gaobo Xu

AI总结:

本文研究了大间距AC-LGAD探测器在不同N+注入剂量下的性能,发现低剂量可改善空间分辨率,时间分辨率抖动基本不变。

摘要:

交流耦合低增益雪崩二极管(AC-LGAD)是基于低增益雪崩二极管(LGAD)技术开发的一种新型4D探测器,能够精确测量粒子的时间和空间信息。高能物理研究所(IHEP)设计了一种大尺寸AC-LGAD,其间距为2000微米,交流焊盘为1000微米,并研究了N+层注入剂量对空间分辨率和时间分辨率的影响。对于约12个最小电离粒子对应的电荷,空间分辨率随N+注入剂量不同在36微米至16微米之间变化。时间分辨率的抖动分量随不同N+注入剂量变化不大,通过激光测量约为15-17皮秒。低N+注入剂量的AC-LGAD具有较大的衰减因子,并且在焊盘之间的中心区域具有更好的空间分辨率。在这些特定条件下,大的信号衰减因子和低的噪声水平有利于提高AC-LGAD传感器的空间分辨率。

英文摘要:

AC-Coupled LGAD (AC-LGAD) is a new 4D detector developed based on the Low Gain Avalanche Diode (LGAD) technology, which can accurately measure the time and spatial information of particles. The Institute of High Energy Physics (IHEP) designed a large-size AC-LGAD with a pitch of 2000~\SI{}{\micro\metre} and AC pad of 1000~\SI{}{\micro\metre}, and explored the effect of N+ layer dose on the spatial resolution and time resolution. The spatial resolution varied from 36~\SI{}{\micro\metre} to 16~\SI{}{\micro\metre} depending on N+ dose for a charge corresponding to about 12 minimum ionizing particles. The jitter component of the time resolution does not change significantly with different N+ doses, and it is about 15-17 ps measured by laser. The AC-LGAD with a low N+ dose has a large attenuation factor and better spatial resolution in the central region between pads. In these specific conditions, large signal attenuation factor and low noise level are beneficial to improve the spatial resolution of the AC-LGAD sensor.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑