An interesting case of the well-known Dataset Shift Problem is the classification of Electroencephalogram (EEG) signals in the context of Brain-Computer Interface (BCI). The non-stationarity of EEG signals can lead to poor generalisation performance in BCI classification systems used in different sessions, also from the same subject. In this paper, we start from the hypothesis that the Dataset Shift problem can be alleviated by exploiting suitable eXplainable Artificial Intelligence (XAI) methods to locate and transform the relevant characteristics of the input for the goal of classification. In particular, we focus on an experimental analysis of explanations produced by several XAI methods on an ML system trained on a typical EEG dataset for emotion recognition. Results show that many relevant components found by XAI methods are shared across the sessions and can be used to build a system able to generalise better. However, relevant components of the input signal also appear to be highly dependent on the input itself.
A Scalable AI Driven, IoT Integrated Cognitive Digital Twin for Multi-Modal Neuro-Oncological Prognostics and Tumor Kinetics Prediction using Enhanced Vision Transformer and XAI
University of Calcutta(加尔各答大学);Institute of Engineering and Management(工程与管理学院);University of Engineering and Management(工程与管理大学);San Francisco State University(旧金山州立大学)
Are we still able to recognize pearls? Machine-driven peer review and the risk to creativity: An explainable RAG-XAI detection framework with markers extraction
Bucharest University of Economic Studies(布加勒斯特经济研究大学)
Painting the black box white: experimental findings from applying XAI to an ECG reading setting
University of Milano-Bicocca(米兰比可卡大学);University of Siena(锡耶纳大学)
从符号AI系统到黑盒、子符号和统计AI系统的转变促使人们对可解释AI(XAI)的兴趣迅速增加,即使黑盒AI系统可解释给人类决策者的方法,目的是使这些系统更容易接受,更有用的工具和支持。然而,我们提出的观点是,而不是总是使黑盒透明,这些方法是在\emph{painting the black boxes white}的风险,从而无法提供一个透明的水平,将增加系统的可用性和可理解性,或者,甚至在产生新的错误,在我们所谓的\emph{white-box paradox}的风险。为了解决这些可用性相关的问题,在这项工作中,我们专注于用户的认知层面的解释和XAI系统。为此,我们设计并进行了一项基于心电图的实验,其中44名心脏病住院医生和专家参与了一项人工智能支持的心电图阅读任务。在此过程中,我们调查了不同的研究问题,涉及用户特征(例如专业知识)与他们对AI和XAI系统的感知之间的关系,包括他们的信任,感知解释的质量和他们将决策过程推迟到自动化(即技术主导)的倾向,以及这些不同维度之间的相互关系。我们的研究结果提供了一个贡献的评估基于人工智能的支持系统从人与人工智能互动为导向的角度,并奠定了基础,为进一步调查XAI及其对决策和用户体验的影响。
When Bias Backfires: The Modulatory Role of Counterfactual Explanations on the Adoption of Algorithmic Bias in XAI-Supported Human Decision-Making
Machine Learning Group, Bielefeld University(比勒菲尔德大学机器学习组);Research Center Trustworthy Data Science and Security of the University Alliance Ruhr, Faculty of Informatics, Technical University Dortmund(鲁尔大学联盟可信数据科学与安全研究所以及多特蒙德技术大学信息学院)
SPDIM: Source-Free Unsupervised Conditional and Label Shift Adaptation in EEG
Nara Institute of Science and Technology (NAIST)(奈良科学技术大学);Department of Dynamic Brain Imaging, ATR(动态脑成像部门,ATR);Center for Advanced Intelligence Project, RIKEN(先进智能项目中心,RIKEN)
SPDAlign: Interpretable Riemannian Alignment for EEG Forward Modeling Shifts
BIFOLD(柏林智能数据与机器学习研究所);Technical University of Berlin(柏林工业大学);Advanced Telecommunications Research Institute International(国际电气通信基础技术研究所);RIKEN AIP(理化学研究所先进智能研究中心);Nanyang Technological University(南洋理工大学)
Geodesic Optimization for Predictive Shift Adaptation on EEG data
Inria(法国国家信息与自动化研究所);CEA(法国原子能和替代能源委员会);Université Paris-Saclay(巴黎萨克雷大学);TAU(特拉维夫大学);LISN-CNRS(法国国家科学研究中心南巴黎大学实验室);Roche Pharma Research and Early Development(罗氏制药研发与早期研发部);Neuroscience and Rare Diseases(神经科学与罕见病部);Roche Innovation Center Basel(罗氏巴塞尔创新中心);F. Hoffmann–La Roche Ltd.(霍夫曼-拉罗什有限公司)
Subject-Specific Analysis of Self-Initiated Attention Shifts from EEG with Controlled Internal and External Attention Conditions
Advanced Institute of Convergence Knowledge Informatics, Tohoku University, Japan(东京东京大学融合知识信息研究院);Graduate School of Information Sciences, Tohoku University, Japan(东京东京大学信息科学研究生院);Center for Data-Driven Science and Artificial Intelligence, Tohoku University, Japan(东京东京大学数据驱动科学与人工智能研究中心);Research Institute of Electrical Communication, Tohoku University, Japan(东京东京大学电气通信研究所)
Siam-ALS: An Explainable Siamese Deep Learning Framework for Early ALS Detection Using EEG and Eye-Tracking Signals
School of Electrical and Electronic Engineering, Shanghai University of Engineering Science(上海工程技术大学电子与电气工程学院);School of Information Technology, Murdoch University(莫道克大学信息技术学院);Daffodil International University(水仙国际大学)
PHINN-EEG: Topological Time-Series Analysis of Dream-State EEG -- Dynamic Betti Curves for Dream Content Classification and Topology-Conditioned Neural Signal Synthesis
Mitigating Subject Dependency in EEG Decoding with Subject-Specific Low-Rank Adapters
Department of Mathematics(数学系);Otto von Guericke University Magdeburg(奥托·冯·格里克大学马格德堡分校);Max Planck Institute for Dynamics of Complex Technical Systems(复杂技术系统动力学马克斯·普朗克研究所);Oak Ridge National Laboratory(橡树岭国家实验室)
RAICL: Retrieval-Augmented In-Context Learning for Vision-Language-Model Based EEG Seizure Detection
Ministry of Education Key Laboratory of Image Processing and Intelligent Control, School of Artificial Intelligence and Automation, Huazhong University of Science and Technology(教育部图像处理与智能控制重点实验室,人工智能与自动化学院,华中科技大学);State Key Laboratory of Brain Cognition and Brain-inspired Intelligence Technology, Institute of Automation, Chinese Academy of Sciences(脑认知与脑启发智能技术国家重点实验室,自动化研究所,中国科学院)
Learning aligned EEG representations with subject-specific encoders
University of São Paulo(圣保罗大学);Université Paris-Saclay, Inria TAU team, LISN-CNRS(巴黎萨克雷大学,Inria TAU团队,LISN-CNRS);Institut de neuromodulation, GHU Paris, psychiatrie et neurosciences, centre hospitalier Sainte-Anne, pôle hospitalo-universitaire 15, Université Paris Cité(神经调控研究所,GHU巴黎,精神病学与神经科学,圣安娜医院,大学医院中心15区,巴黎西岱大学);Federal University of ABC (UFABC)(ABC联邦大学);Yneuro;Swartz Center for Computational Neuroscience (SCCN), Institute for Neural Computation (INC), University of California San Diego(斯沃茨计算神经科学中心,神经计算研究所,加州大学圣地亚哥分校)