使用设置传递函数校准基于深度学习的定量超声中的数据失配

Calibrating Data Mismatches in Deep Learning-Based Quantitative Ultrasound Using Setting Transfer Functions

Ufuk Soylu, Michael L. Oelze

摘要:

当训练数据和测试数据之间存在数据不匹配时,深度学习(DL)可能会失败。由于其依赖于操作员的性质,在超声成像中可能发生由不同的扫描仪设置引起的采集相关数据不匹配。因此,减轻这种数据不匹配的影响对于更广泛地临床采用DL供电的超声成像至关重要。为了减轻影响,理想情况下,我们需要在每个扫描仪设置下收集一个大型训练集。然而,获取这样的训练集是昂贵的。另一种方法可以是在成像设置的子集上进行训练,这使得数据生成成本更低。但是,仍然存在泛化问题。作为一种替代方法,这是廉价的和可推广的,我们建议收集一个大的训练集在一个单一的设置和一个小的校准集在每个扫描仪设置。然后,校准集将用于通过使用信号和系统的角度来校准数据失配。我们测试了所提出的解决方案,以分类两个幻影。为了研究所提出的解决方案的通用性,我们校准了三种类型的数据失配:脉冲频率,焦点和输出功率失配。为了校准设置不匹配,我们计算了设置传递函数。在没有校准的情况下训练的CNN对于脉冲频率、焦点和输出功率失配分别产生55.3%、64.4%和70.3%的平均分类准确度。通过使用设置的传递函数,它允许匹配的训练和测试域,我们得到的平均准确率分别为95.3%,92.99%和99.32%。因此,在扫描器设置之间合并设置传递函数可以提供用于特定分类任务的DL模型的一般化的经济手段,其中扫描器设置不由操作员固定。

英文摘要:

Deep learning (DL) can fail when there are data mismatches between training and testing data. Due to its operator-dependent nature, acquisition-related data mismatches, caused by different scanner settings, can occur in ultrasound imaging. Therefore, mitigating effects of such data mismatches is essential for wider clinical adoption of DL powered ultrasound imaging. To mitigate the effects, ideally we need to collect a large training set at each scanner setting. However, acquiring such training sets is expensive. Another approach could be training on a subset of imaging settings, which makes the data generation less expensive. However, there will still be generalization issues. As an alternative approach that is inexpensive and generalizable, we propose to collect a large training set at a single setting and a small calibration set at each scanner setting. Then, the calibration set will be used to calibrate data mismatches by using a signals and systems perspective. We tested the proposed solution to classify two phantoms. To investigate generalizability of the proposed solution, we calibrated three types of data mismatches: pulse frequency, focus and output power mismatches. To calibrate the setting mismatches, we calculated the setting transfer functions. The CNN trained with no calibration resulted in mean classification accuracies of 55.3%, 64.4% and 70.3% for pulse frequency, focus and output power mismatches, respectively. By using the setting transfer functions, which allowed a matching of the training and testing domains, we obtained mean accuracies of 95.3%, 92.99% and 99.32%, respectively. Therefore, the incorporation of the setting transfer functions between scanner settings can provide an economical means of generalizing a DL model for specific classification tasks where scanner settings are not fixed by the operator.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑