Atom-based radio frequency electromagnetic field sensing using atomic Rydberg states is a promising technique that has recently attracted significant interest. Its unique advantages, such as extraordinary bandwidth, self-calibration and all-dielectric sensors, are a tangible improvement over antenna-based methods in applications such as test and measurement, and development of broad bandwidth receivers. Here, we demonstrate how an optical frequency comb can be used to acquire data in the Autler-Townes regime of Rydberg atom-based electrometry in a massively parallel fashion, eliminating the need for laser scanning. Two-photon electromagnetically induced transparency read-out and preparation of cesium is used for the demonstration. A flat, quasi-continuous optical comb is generated with the probe laser at 852 nm using an electro-optic modulator and arbitrary waveform generator. A single frequency coupling laser at 509 nm is tuned to the Rydberg launch state. An enhanced transmission signal is obtained using self-heterodyne spectroscopy. The comb signal is beat against a local oscillator derived from the single frequency probe laser on a fast photodiode. The transmission of each probe laser comb tooth is observed. We resolve electromagnetically induced transparency peaks with linewidths below 5 MHz, with and without laser locking. Radio frequency electromagnetic fields as low as 66 $μ$Vcm$^{-1}$ are detected with sensitivities of 2.3 $μ$Vcm$^{-1}$Hz$^{-1/2}$. The method offers a significant advantage for reading-out electromagnetically induced transparency and Autler-Townes splitting as neither laser needs to be scanned and slow frequency drifts can be tolerated in some applications. The method enables the detection of the amplitude of a pulsed radio frequency electromagnetic field when the incoming pulse Autler-Townes splits the electromagnetically induced transparency peak.
Floquet-sideband-enhanced shortwave electrometry with Rydberg atoms
Xi’an Jiaotong University(西安交通大学);Nanjing University(南京大学);Beijing Institute of Radio Metrology and Measurement(北京无线电计量测试研究所);East China Normal University(华东师范大学);Hefei National Laboratory(合肥国家实验室);University of Arkansas(阿肯色大学)
Ultrastable frequency reference at 1.56 μm using a CO molecular overtone transition with the noise immune cavity-enhanced optical heterodyne molecular spectroscopy method
报道了一种基于一氧化碳12 C 16 O在1563 nm处的3ν振转结合带的超稳分子钟。激光稳定方案是基于频率调制(FM)饱和光谱在高精细度超低膨胀(ULE)玻璃光学腔中使用CO作为长期稳定腔谐振的分子参考。采用NICEOHMS FM调制方法,以保持高的信噪比,并避免由高精细度腔将激光频率噪声转换为幅度噪声。我们报告1秒时的艾伦偏差为1.8x10-12,在1000秒的平均后提高到3.5x10-14。
Electrometry of extremely-low frequencies from kHz to sub-Hz with a Rydberg-atom sensor
Centre for Quantum Technologies, National University of Singapore(新加坡国立大学量子技术中心);School of Physical and Mathematical Sciences, Nanyang Technological University(南洋理工大学物理与数学科学学院);Department of physics and Materials Science, Chiang Mai University(清迈大学物理与材料科学系);Quantum Sensing Centre(量子传感中心)
Injection locking of two frequency-doubled lasers with 3.2 GHz offset for driving Raman transitions with low photon scattering in $^{43}$Ca$^+$
我们描述了两个红外(794 nm)激光二极管,这是每个倍频激光系统的一部分的注入锁定。注入路径中的声光调制器(AOM)在激光器之间给出1.6GHz的偏移,用于驱动$^{43}$ Ca $^+$的超精细分裂(3.2GHz)基态中的状态之间的拉曼跃迁。可以禁用偏移以在$^{40}$ Ca $^+$中使用。我们测量的相对线宽的倍频光束为42兆赫的光外差测量。注入锁定和倍频两者的使用将光谱纯度与高光功率结合。我们的方案是适用于提供拉曼光束跨越其他离子物种和中性原子的相干光学操纵是必需的。