The concentration of radon in the air has been measured in the 700 m-deep Yangyang underground laboratory between October 2004 and May 2022. The average concentrations in two experimental areas, called A6 and A5, were measured to be 53.4$\pm$0.2 Bq/m3 and 33.5$\pm$0.1 Bq/m3, respectively. The lower value in the A5 area reflects the presence of better temperature control and ventilation. The radon concentrations sampled within the two A5 experimental rooms' air are found to be correlated to the local surface temperature outside of the rooms, with correlation coefficients r = 0.22 and r = 0.70. Therefore, the radon concentrations display a seasonal variation, because the local temperature driven by the overground season influences air ventilation in the experimental areas. A fit on the annual residual concentrations finds that the amplitude occurs each year on August, 31$\pm$6 days.
Initial performance of the high sensitivity alpha particle detector at the Yangyang underground laboratory
本文介绍了韩国700米深的阳阳地下实验室的UltraLo-1800 α粒子探测器的初步性能。电离检测器使用氩气作为测量样品α事件的计数气体。我们目前的初步校准结果和低活性样品测量的基础上探测器的脉冲歧视的方法和硬件否决。提出了一种可能性分析,该分析显示使用模拟模型从具有来自$^{210}$ Po α粒子的污染深度的表面组分分离本体组分。
Environmental radon control in the 700-m underground laboratory at JUNO
Institute of High Energy Physics, Chinese Academy of Sciences(中国科学院高能物理研究所);University of Chinese Academy of Sciences(中国科学院大学);INFN Milano Bicocca and Università di Milano-Bicocca(意大利国家核物理研究所米兰比科卡分部和米兰比可卡大学)
Measurement of radon concentration in the output water of the 100~t/h ultrapure water system at the Jiangmen Underground Neutrino Observatory
University of South China(南华大学);Institute of High Energy Physics, Chinese Academy of Sciences(中国科学院高能物理研究所);University of Chinese Academy of Sciences(中国科学院大学);State Key Laboratory of Particle Detection and Electronics(粒子探测与电子学国家重点实验室);Anhui University of Science and Technology(安徽理工大学)
In-situ suppression of surface radon emanation using an HDPE barrier at the Stawell Underground Physics Laboratory (SUPL)
Australian National University(澳大利亚国立大学);Stawell Underground Physics Laboratory, via Stawell Gold Mines(斯塔韦尔地下物理实验室,经斯塔韦尔金矿);Adelaide University(阿德莱德大学);Swinburne University of Technology(斯威本科技大学);University of Sheffield(谢菲尔德大学);ARC Centre of Excellence for Dark Matter Particle Physics(暗物质粒子物理学卓越研究中心)
A new ultra low-level HPGe activity counting setup in the Felsenkeller shallow-underground laboratory
一个新的超低水平计数装置已经安装在德国德累斯顿的浅层地下实验室Felsenkeller。它包括一个高纯度锗探测器(HPGe),在被动和主动屏蔽内的相对效率为163\%。被动屏蔽层由45米的岩石覆盖层(140米水当量),40厘米的低活性混凝土和一个由防氡盒包围的铅和铜城堡组成。被动屏蔽单独被发现,以减少本底率的速率相媲美的其他浅地下实验室。一个额外的积极否决权是由五个大型塑料闪烁板周围的设置。在40-2700 keV的能量区间内,它进一步将本底速率降低一个数量级以上,降至116 $\pm$ 1 kg $^{-1}$ d $^{-1}$。如此低的本底率对于浅地下实验室和接近深地下实验室来说是前所未有的。