arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2208.07348astro-ph.IMastro-ph.HE
收藏

了解下一代软X射线成像仪中电荷扩散的影响

Understanding the effects of charge diffusion in next-generation soft X-ray imagers

Eric D. Miller, Gregory Y. Prigozhin, Beverly J. LaMarr, Marshall W. Bautz, Richard F. Foster, Catherine E. Grant, Craig S. Lage, Christopher Leitz, Andrew Malonis

摘要:

为了利用对宽能量范围敏感的高分辨率光学器件,未来的X射线成像仪器将需要具有小像素的厚探测器。该像素纵横比影响软X射线波段中的光谱响应,这对于许多科学目标至关重要,因为入射窗口附近的光子相互作用产生的电荷在收集时扩散到多个像素上,并且在施加的噪声阈值以下可能会丢失。为了理解这些微妙但重要的影响,并告知未来探测器的设计和要求,我们提出了使用各种探测器特性和操作设置的电荷扩散模拟,评估在X射线能量范围内的光谱响应。我们通过将性能与在实验室中测试并部署在太空中的真实CCD探测器的性能进行比较来验证模拟,这些CCD探测器跨越了一系列厚度,像素大小和其他特性。模拟表明,虽然较大的像素,较高的偏置电压,和最佳的背面钝化提高性能,降低读出噪声在所有情况下具有主导作用。最后,我们将展示如何高像素纵横比设备提出的挑战,测量背面钝化性能由于其他工艺的幅度,降低光谱响应,并提出了一种方法,利用模拟定性评估这种性能。由于引人注目的科学要求往往在技术上相互竞争(高空间分辨率,软X射线响应,硬X射线响应),这些结果可以用来找到未来高空间分辨率X射线仪器的适当平衡。

英文摘要:

To take advantage of high-resolution optics sensitive to a broad energy range, future X-ray imaging instruments will require thick detectors with small pixels. This pixel aspect ratio affects spectral response in the soft X-ray band, vital for many science goals, as charge produced by the photon interaction near the entrance window diffuses across multiple pixels by the time it is collected, and is potentially lost below the imposed noise threshold. In an effort to understand these subtle but significant effects and inform the design and requirements of future detectors, we present simulations of charge diffusion using a variety of detector characteristics and operational settings, assessing spectral response at a range of X-ray energies. We validate the simulations by comparing the performance to that of real CCD detectors tested in the lab and deployed in space, spanning a range of thickness, pixel size, and other characteristics. The simulations show that while larger pixels, higher bias voltage, and optimal backside passivation improve performance, reducing the readout noise has a dominant effect in all cases. We finally show how high-pixel-aspect-ratio devices present challenges for measuring the backside passivation performance due to the magnitude of other processes that degrade spectral response, and present a method for utilizing the simulations to qualitatively assess this performance. Since compelling science requirements often compete technically with each other (high spatial resolution, soft X-ray response, hard X-ray response), these results can be used to find the proper balance for a future high-spatial-resolution X-ray instrument.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑