Thermal Testing for Cryogenic CMB Instrument Optical Design
D. C. Goldfinger, P. A. R. Ade, Z. Ahmed, M. Amiri, D. Barkats, R. Basu Thakur, D. Beck, C. A. Bischoff, J. J. Bock, V. Buza, J. Cheshire, J. Connors, J. Cornel… 展开作者
D. C. Goldfinger, P. A. R. Ade, Z. Ahmed, M. Amiri, D. Barkats, R. Basu Thakur, D. Beck, C. A. Bischoff, J. J. Bock, V. Buza, J. Cheshire, J. Connors, J. Cornelison, M. Crumrine, A. J. Cukierman, E. V. Denison, M. I. Dierickx, L. Duband, M. Eiben, S. Fatigoni, J. P. Filippini, C. Giannakopoulos, N. Goeckner-Wald, J. Grayson, P. K. Grimes, G. Hall, G. Halal, M. Halpern, E. Hand, S. A. Harrison, S. Henderson, S. R. Hildebrandt, G. C. Hilton, J. Hubmayk, H. Hui, K. D. Irwin, J. Kang, K. S. Karkare, S. Kefeli, J. M. Kovac, C. L. Kuo, K. Lau, E. M. Leitch, A. Lennox, T. Liu, K. G. Megerian, L. Minutolo, L. Moncelsi, Y. Nakato, T. Namikawa, H. T. Nguyen, R. O'Brient, S. Palladino, M. A. Petroff, T. Prouve, C. Pryke, B. Racine, C. D. Reintsema, M. Salatino, A. Schillaci, B. L. Schmitt, B. Singari, A. Soliman, A. G. Smith, T. St. Germaine, B. Steinbach, R. V. Sudiwala, K. L. Thompson, C. Tsai, C. Tucker, A. D. Turner, C. Umiltà, C. Vergès, A. G. Vieregg, A. Wandui, A. C. Weber, D. V. Wiebe, J. Willmert, W. L. K. Wu, H. Yang, K. W. Yoon, E. Young, C. Yu, L. Zeng, C. Zhang, S. Zhang
Observations of the Cosmic Microwave Background rely on cryogenic instrumentation with cold detectors, readout, and optics providing the low noise performance and instrumental stability required to make more sensitive measurements. It is therefore critical to optimize all aspects of the cryogenic design to achieve the necessary performance, with low temperature components and acceptable system cooling requirements. In particular, we will focus on our use of thermal filters and cold optics, which reduce the thermal load passed along to the cryogenic stages. To test their performance, we have made a series of in situ measurements while integrating the third receiver for the BICEP Array telescope. In addition to characterizing the behavior of this receiver, these measurements continue to refine the models that are being used to inform design choices being made for future instruments.
Sub-Kelvin Cryogenics for a Super-Pressure Balloon-Borne CMB Polarimeter: Taurus
Case Western Reserve University(凯斯西储大学);University of California, Berkeley(加州大学伯克利分校);Lawrence Berkeley National Laboratory(劳伦斯伯克利国家实验室);National Institute of Standards and Technology(美国国家标准与技术研究院);Princeton University(普林斯顿大学);University of Colorado Boulder(科罗拉多大学博尔德分校);University of Illinois Urbana-Champaign(伊利诺伊大学厄巴纳-香槟分校);University of Iceland(冰岛大学);Stockholm University(斯德哥尔摩大学)
The Simons Observatory: Overview of the Cryogenic Half-wave Plate Polarization Modulators
University of California Riverside(加州大学河滨分校);Princeton University(普林斯顿大学);University of California San Diego(加州大学圣地亚哥分校);The University of Tokyo(东京大学);The Suwa University of Science(信州大学(原諏訪科學大學));University of Texas at Austin(德克萨斯大学奥斯汀分校);Lawrence Berkeley National Laboratory(劳伦斯伯克利国家实验室)
A Cryogenic SiGe Low Noise Amplifier Optimized for Phased Array Feeds
越来越多的射电天文相控阵馈源(PAF)表明,对低噪声放大器(LNA)的需求日益增加,这些放大器的设计具有可重复性、低噪声和易于制造的特点。有助于实现这些目标的具体设计功能包括使用未封装晶体管(用于低温操作)、单极性偏置、便于安装和返工的直插入式RF接口以及使用现成组件。绿岸望远镜(英语:Green Bank Telescope)(FLAG)的焦点L波段阵列是杨百翰大学(英语:Brigham Young University)(BYU)和国家射电天文台(英语:National Radio Astronomy Observatory)(NRAO)的合作成果,使用了暖偶极天线和低温硅锗异质结双极晶体管(SiGe HBT)LNA。这些LNA具有38 dB的带内增益平均值和4.85开尔文平均噪声温度。虽然FLAG仪器是这一发展背后的驱动仪器,但设计的大多数关键特征及其提供的优势广泛适用于其他阵列馈电,包括独立波束和相控,以及许多天线类型,如喇叭,偶极子,Vivaldi,连接蝴蝶结,本文将重点讨论阵列馈电对低噪声放大器的独特要求,以及放大器制造如何满足这些要求。
Cryogenic characterization of the Planck sorption cooler system flight model
本文是JINST上发表的发射前状态LFI论文的一部分:http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221喷气推进实验室(JPL)为欧洲航天局(ESA)普朗克任务制造和组装了两个连续闭合循环氢焦耳-汤姆逊(J-T)吸附冷却器。每个制冷机的设计目的是在两个仪器接口处提供总计约1 W的冷却功率:它们直接冷却普朗克低频仪器(LFI)约20 K,同时为高频仪器(HFI)的4 K J-T机械制冷机提供预冷级。在喷气推进实验室进行子系统级验证后,低温冷却器已于2005年交付欧空局。在本文中,我们介绍了2008年在CSL(Centre Spatial de Liege)设施进行的飞行模型航天器上标称装置的低温鉴定和试验活动的结果。测试结果的输入功率,冷却功率,温度和温度波动的飞行允许范围内,这些接口的报告和分析任务的要求。
Opening the low-background and high-spectral-resolution domain with the ATHENA large X-ray observatory: Development of the Cryogenic AntiCoincidence Detector for the X-ray Integral Field Unit
Instrumental development for Cryogenic sub-Hz cROss torsion bar detector with quantum NOn-demolition Speed meter (CHRONOS)
Institute of Physics, Academia Sinica(中央研究院物理研究所);Center for High Energy and High Field Physics (CHiP), National Central University(国立中央大学高能高场物理中心);Department of Physics, National Central University(国立中央大学物理系);Institute of Particle and Nuclear Studies, High Energy Accelerator Research Organization (KEK)(高能加速器研究机构粒子与核研究部);National Institute of Physics, University of the Philippines - Diliman(菲律宾大学迪利曼分校国家物理研究所)
The Precursor Small Aperture Telescope (PreSAT) CMB polarimeter
Center for Astrophysics, Harvard & Smithsonian(哈佛-史密森天体物理中心);Kavli Institute for Particle Astrophysics and Cosmology, SLAC National Accelerator Laboratory(卡弗里粒子天体物理学与宇宙学研究所,SLAC国家加速器实验室);Department of Physics, California Institute of Technology(加州理工学院物理系);Jet Propulsion Laboratory(喷气推进实验室);Minnesota Institute for Astrophysics, School of Physics and Astronomy, University of Minnesota(明尼苏达大学物理与天文学院天体物理研究所);Department of Physics and Astronomy, University of Pennsylvania(宾夕法尼亚大学物理与天文学系);Department of Physics, Enrico Fermi Institute, Kavli Institute for Cosmological Physics, University of Chicago(芝加哥大学物理系,恩里科·费米研究所,卡弗里宇宙物理学研究所)
CCAT: Mod-Cam Cryogenic Performance and its Impact on 280 GHz KID Array Noise
Cornell University(康奈尔大学);Duke University(杜克大学);National Institute of Standards and Technology(美国国家标准与技术研究院);University of British Columbia(不列颠哥伦比亚大学);Dalhousie University(达尔豪斯大学);University of California, Riverside(加州大学河滨分校);Arizona State University(亚利桑那州立大学);NASA Goddard Space Flight Center(NASA戈达德太空飞行中心)
Setting requirements on out-of-band rejection for next-generation CMB experiments. Application to the LiteBIRD instrument
Université Paris-Saclay(巴黎萨克雷大学);CNRS(法国国家科学研究中心);Institut d’Astrophysique Spatiale(空间天体物理研究所);IRAP(天体物理学研究所);Université de Toulouse(图卢兹大学);CNES(法国国家空间研究中心);Università La Sapienza(罗马第一大学);INFN Sezione di Roma(意大利国家核物理研究院罗马分部);Université Paris Cité(巴黎西岱大学);Astroparticule et Cosmologie(粒子天体物理与宇宙学实验室);Università degli Studi di Milano(米兰大学);INFN Sezione di Milano(意大利国家核物理研究院米兰分部);Cardiff University(卡迪夫大学);High Energy Accelerator Research Organization (KEK)(高能加速器研究机构);Kavli Institute for the Physics and Mathematics of the Universe (Kavli IPMU, WPI), UTIAS, The University of Tokyo(东京大学 Kavli宇宙粒子物理中心);NIST Quantum Sensors Group(美国国家标准与技术研究院量子传感器小组)
Optimising the multiplex factor of the frequency domain multiplexed readout of the TES-based microcalorimeter imaging array for the X-IFU instrument on the Athena Xray observatory
Diamond-loaded polyimide aerogel scattering filters and their applications in astrophysical and planetary science observations
The University of Maryland, Baltimore County(马里兰大学巴尔的摩分校);NASA Goddard Space Flight Center(美国宇航局戈达德太空飞行中心);The Johns Hopkins University(约翰斯·霍普金斯大学);Boston University(波士顿大学);Universities Space Research Association(大学空间研究协会);NASA Glenn Research Center(美国宇航格伦研究中心)
SPECTER: An Instrument Concept for CMB Spectral Distortion Measurements with Enhanced Sensitivity
Columbia University(哥伦比亚大学);University of California, Berkeley(加州大学伯克利分校);Lawrence Berkeley National Laboratory(劳伦斯伯克利国家实验室);Stanford University(斯坦福大学);University of Chicago(芝加哥大学)
Recovery of Large Angular Scale CMB Polarization for Instruments Employing Variable-delay Polarization Modulators
可变延迟偏振调制器(VPM)目前被用于在大角度尺度上测量宇宙微波背景的偏振的实验中,因为它们能够提供快速的前端偏振调制和对系统误差的控制。尽管VPM提供了诸多优势,但识别和减轻泄漏到信号的同步调制分量中的任何时变效应也很重要。在本文中,从一个$300$ K VPM的排放对系统性能的影响被认为是和解决。虽然仪器设计可以大大降低调制VPM发射的影响,但仍会有一些残留的调制信号。VPM的排放处理中存在的旋转失调和温度变化。时序数据的模拟被用来评估这些残余误差对功率谱的影响。本文中的分析和建模指导实验人员使用VPM作为前端调制器的观测的关键方面。通过实现所描述的表征和控制,前端VPM调制对于减轻大角度尺度极化测量中的$1/f$噪声可以是非常强大的。研究的系统误差从根本上限制了张量标量比为$r=0.01$的大尺度B模式的检测和表征。事实上,$r<0.01$可以通过显著改进的表征和控制来实现。
Precision Tests of Parity Violation Over Cosmological Distances
最近通过BICEP 2和POLARBEAR实验对宇宙微波背景$B$模式偏振功率谱的测量已经展示了用于探测基础物理的新的精确工具。不管起源如何,我们能够检测到亚$μ$ K CMB偏振的事实代表了巨大的技术突破。然而,更多的信息可能隐藏在CMB的极化模式中。由于它的张量性质,CMB偏振也可以通过检测宇宙偏振旋转来揭示宇称违反物理学。虽然目前的CMB偏振仪是足够灵敏的测量一个度级偏振旋转与$>5σ$统计意义,他们缺乏区分这种效果从一个系统的仪器偏振旋转的能力。在这里,我们激励从目前的CMB数据以及独立的射电星系和类星体的偏振测量宇宙偏振旋转的搜索。我们认为,校准精度的提高将允许精确测量的奇偶性和洛伦兹违反效果。我们描述了CalSat天基偏振校准器,该校准器将为$0.05^\circ$提供系统偏振角校准不确定性的严格控制--比当前CMB偏振校准器有一个数量级的改进。基于CalSat-based校准可以与当前的CMB偏振仪一起使用,以搜索$B$模式偏振,有效地将它们变成宇宙宇称违反的探测器,即不需要建立专用仪器。