对3D打印部件进行质谱研究,以评估作为稀有事件物理探测器超低背景材料的放射性纯度
Mass spectrometric investigations into 3D printed parts to assess radiopurity as ultralow background materials for rare event physics detectors
摘要:
报告了聚偏二氟乙烯(PVDF)、聚苯硫醚(PPS)和两种形式的聚醚酰亚胺(PEI,品牌为ULTEM 1010和9085)的新数据。报告了起始细丝以及简单和复杂印刷部件的数据。发现PVDF细丝和简单的印刷珠分别具有大约30和50 ppt的Th-232和U-238值,而更复杂的弹簧夹部分具有略微升高的65 ppt的Th-232水平,而U-238保持在50 ppt。发现PPS长丝的Th-232和U-238浓度分别为270和710 ppt,并且没有选择打印,因为这些水平已经高于其他材料选项。发现ULTEM 1010细丝和印刷的复杂弹簧夹部件的Th-232和U-238浓度分别约为5和7 ppt,说明印刷过程没有显著污染。发现ULTEM 9085细丝的Th-232和U-238的浓度分别为约9和5 ppt,而发现印刷的复合弹簧夹部分的Th-232和U-238的浓度分别为25和7 ppt。这些结果都是使用一种新的干灰化方法在坩埚超低背景电铸铜或,适用时,微波辅助湿灰化消化。在干/湿灰化之前,向样品和工艺空白中加入Th-229和U-233作为内标物,并通过电感耦合等离子体质谱法(ICP-MS)进行测定。为了保持高放射性纯度水平,建议在打印前对细丝进行预清洁,并对部件进行后清洁,尽管打印过程本身已显示出非常微量的放射性污染物。
英文摘要:
New data are reported for polyvinylidene fluoride (PVDF), polyphenylene sulfide (PPS), and two forms of polyetherimide (PEI, branded ULTEM 1010 and 9085). Data for starting filaments and both simple and complex printed parts are reported. PVDF filaments and simple printed beads, were found to have values of approximately 30 and 50 ppt for Th-232 and U-238, respectively, while a more complex spring clip part had slightly elevated Th-232 levels of 65 ppt, with U-238 remaining at 50 ppt. PPS filament was found to have concentrations of 270 and 710 ppt for Th-232 and U-238, respectively, and were not chosen to be printed as those levels were already higher than other material options. ULTEM 1010 filaments and printed complex spring clip parts were found to have concentrations of around 5 and 7 ppt for Th-232 and U-238, respectively, illustrating no significant contamination from the printing process. ULTEM 9085 filaments were found to have concentrations of around 9 and 5 ppt for Th-232 and U-238, respectively, while the printed complex spring clip part was found to have slightly elevated concentrations of 25 and 7 ppt for Th-232 and U-238, respectively. These results were all obtained using a novel dry ashing method in crucibles constructed of ultralow background electroformed copper or, when applicable, microwave-assisted wet ashing digestion. Samples and process blanks were spiked with Th-229 and U-233 as internal standards prior to dry/wet ashing and determinations were made by inductively coupled plasma mass spectrometry (ICP-MS). In order to maintain high radiopurity levels, pre-cleaning the filaments before printing and post-cleaning the parts is recommended, although the printing process itself has shown to contribute very minute amounts of radiocontaminants.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。