用于评估作为稀有事件物理探测器超低本底材料的高性能聚合物的质谱分析
Mass spectrometric analyses of high performance polymers to assess radiopurity as ultra low background materials for rare event physics detectors
摘要:
Th-232和U-238的质量浓度在几个强大的,未填充的,高性能聚合物的报告作为其放射性纯度的措施。在稀有事件物理探测器的构造中,需要高度放射纯的聚合物作为介电材料,以使由探测器材料本身产生的背景信号最小化。报告了聚醚醚酮(PEEK)、聚醚酮酮(PEKK)、聚酰胺酰亚胺(PAI,品牌为Torlon)和聚苯并咪唑(PBI)的精心采购样品的新数据。还讨论了固体聚醚酰亚胺(PEI)的数据,并报告了商业3D打印长丝原料形式的PEI的新数据。发现强高性能聚合物PEKK,PBI,PAI和PEI的Th-232和U-238水平低于1毫Bq/kg,包括PEI 3D打印丝。具体来说,对于Th-232和U-238,以微Bq/kg计,我们发现Arkema Kepstan PEKK 6002薄片的值分别为149和184; Solvay Ketaspire PEEK薄片的值为69和2250; PBI Performance Products低金属级100目PBI粉末的值为346和291; Drake Plastics PAI Torlon T-4200颗粒的值为66和105; Drake Plastics固化PAI棒为401和285; Ensinger PEI Ultem 1000固体为32和41; ThermaX PEI Ultem 1010长丝材料为15和85 microBq/kg。这些结果都是使用一种新的干灰化方法在超低背景(ULB)电铸铜构成的坩埚。在灰化之前,将T-229 h和U-233作为内标物加标样品,并通过电感耦合等离子体质谱法(ICP-MS)进行测定。放射性纯度显示图形相对于这些和其他几种聚合物的机械强度的数值测量。
英文摘要:
The mass concentrations of Th-232 and U-238 in several strong, unfilled, high performance polymers are reported as measures of their radiopurity. Highly radiopure polymers are required as dielectric materials in the construction of rare event physics detectors, in order to minimize background signals arising from the detector materials themselves. New data are reported for carefully sourced samples of polyetheretherketone (PEEK), polyetherketoneketone (PEKK), a polyamide imide (PAI, branded as Torlon) and polybenzimidazole (PBI). Data for solid polyetherimide (PEI) are also discussed and new data for PEI in the form of a commercial 3D printing filament stock are reported. Strong high performance polymers PEKK, PBI, PAI and PEI were found with levels for Th-232 and U-238 that are below one milliBq/kg, including the PEI 3D printing filament. Specifically, for Th-232 and U-238 respectively, in microBq/kg, we found values of 149 and 184 for Arkema Kepstan PEKK 6002 flake; 69 and 2250 for Solvay Ketaspire PEEK flake; 346 and 291 for PBI Performance Products low metals grade 100 mesh PBI powder; 66 and 105 for Drake Plastics PAI Torlon T-4200 pellets; 401 and 285 for Drake Plastics cured PAI rod; 32 and 41 for Ensinger PEI Ultem 1000 solid; and 15 and 85 microBq/kg, for ThermaX PEI Ultem 1010 filament material. These results were all obtained using a novel dry ashing method in crucibles constructed of ultra low background (ULB) electroformed copper. Samples were spiked with T-229h and U-233 as internal standards prior to ashing and determinations were made by inductively coupled plasma mass spectrometry (ICP-MS). Radiopurity is displayed graphically relative to numerical measures of mechanical strength for these and several other polymers.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。