A unified method for three-dimensional reconstruction of objects from transmission images collected at multiple illumination directions is described. The method may be applicable to experimental conditions relevant to absorption-based, phase-contrast or diffraction imaging using X-rays, electrons and other forms of penetrating radiation or matter waves. Both the phase retrieval (also known as contrast transfer function correction) and the effect of Ewald sphere curvature (in the cases with a shallow depth of field and significant in-object diffraction) are incorporated in the proposed algorithm and can be taken into account. Multiple scattering is not treated explicitly, but can be mitigated as a result of angular averaging that constitutes an essential feature of the method. The corresponding numerical algorithm is based on three-dimensional gridding which allows for fast computational implementation, including a straightforward parallelization. The algorithm can be used with any scanning geometry involving plane-wave illumination. A software code implementing the proposed algorithm has been developed, tested on simulated and experimental image data and made publicly available.
Combining optical diffraction tomography with imaging flow cytometry for characterizing morphology, hemoglobin content, and membrane deformability of live red blood cells
X-ray diffraction tomography (XDT) resolves spatially-variant XRD profiles within macroscopic objects, and provides improved material contrast compared to the conventional transmission-based computed tomography (CT). However, due to the small diffraction cross-section, XDT suffers from long imaging acquisition time, which could take tens of hours for a full scan using a table-top X-ray tube. In medical and industrial imaging applications, oftentimes only the XRD measurement within a region-of-interest (ROI) is required, which, together with the demand to reduce imaging time and radiation dose …
Fluorescence molecular tomography (FMT) has potential of providing high contrast images for breast tumor detection. Computational phantom provides a convenient way to a wide variety of fluorophore distribution configurations in patients and perform comprehensive evaluation of the imaging systems and methods for FMT. In this study, a digital breast phantom was used to compare the performance of a novel sparsity-based reconstruction method and Tikhonov regularization method for resolving tumors with different amount of separation. The results showed that the proposed sparse reconstruction method…
Medical imaging modalities have revolutionized health-care approaches by offering a better understanding of the human anatomy. Discovery of x-rays allowed the exploiting of the micro-scaled information of human anatomy. Computed tomography is one of the well-known imaging modalities using x-rays to create images of medical and non-medical objects. CT imaging has several variety of applications from medical diagnosis to industrial non-destructive testing. In this paper, we review computed tomography imaging modality and its applications in screening, diagnosis, and treatment and study some of t…
Interior tomography is a typical strategy for radiation dose reduction in computed tomography, where only a certain region-of-interest (ROI) is scanned. However, given the truncated projection data, ROI reconstruction by conventional analytical algorithms may suffer from severe cupping artifacts. In this paper, we proposed a new extraction-based deep learning method for the reconstruction of interior tomography. Our approach works in dual domains where a sinogram-domain network (SDNet) estimates the contribution of the exterior region to the truncated projection and an image-domain network (ID…
A practical local tomography reconstruction algorithm based on known subregion
ESRF(欧洲同步辐射装置);Université de Grenoble(格勒诺布尔大学);GIPSA-lab - Grenoble Images Parole Signal Automatique - Institut Polytechnique de Grenoble(格勒诺布尔综合理工学院GIPSA实验室——格勒诺布尔图像语音信号自动化实验室)
When the inverse problem of diffuse optical tomography (DOT) is solved with the Born or Rytov approximation, the size of the matrix of the linear inverse problem becomes large if the volume (or area) of the domain in biological tissue used for reconstruction is large. The number of unknown parameters in DOT is reduced when constraints about the shape of a target are imposed for the inverse problem. Due to such constraints, the inverse problem becomes nonlinear even when the (first) Born or Rytov approximation is employed. We solve this nonlinear inverse problem by the simulated annealing, whic…
Dictionary-Learning-Based Reconstruction Method for Electron Tomography
Wake Forest University Health Sciences(维克森林大学健康科学学院);Institute of High Energy Physics, CAS(中国科学院高能物理研究所);Virginia Tech(弗吉尼亚理工大学);University of California, Irvine(加利福尼亚大学欧文分校);Rensselaer Polytechnic Institute(伦斯勒理工学院)
The newly developed Core Imaging Library (CIL) is a flexible plug and play library for tomographic imaging with a specific focus on iterative reconstruction. CIL provides building blocks for tailored regularised reconstruction algorithms and explicitly supports multichannel tomographic data. In the first part of this two-part publication, we introduced the fundamentals of CIL. This paper focuses on applications of CIL for multichannel data, e.g., dynamic and spectral. We formalise different optimisation problems for colour processing, dynamic and hyperspectral tomography and demonstrate CIL's …
We present a reconstruction method involving maximum-likelihood expectation maximization (MLEM) to model Poisson noise as applied to fluorescence molecular tomography (FMT). MLEM is initialized with the output from a sparse reconstruction-based approach, which performs truncated singular value decomposition-based preconditioning followed by fast iterative shrinkage-thresholding algorithm (FISTA) to enforce sparsity. The motivation for this approach is that sparsity information could be accounted for within the initialization, while MLEM would accurately model Poisson noise in the FMT system. S…
We present and evaluate the application of the "Reconstructed Image from Simulations Ensemble" (RISE), a novel tomographic image reconstruction method, in infrared tomography. We demonstrate that established methods of photon emission tomography, widely used with penetrating ionizing radiation, are applicable to infrared radiation. RISE, the method of choice, employs statistical physics concepts and utilizes Monte Carlo techniques to construct the imaged object from its infrared planar projections. The validity of the InfraRed Emission Tomographic (IRET) method is demonstrated, and the efficac…
This paper proposes the combination of SAR and microwave reflection tomography for biomedical imaging applications. The proposed method can achieve accuracies of less than 5mm and does not suffer from instability during reconstruction. Fourier based reconstruction is adopted which makes it fast and computationally efficient.
J-PET Framework is an open-source software platform for data analysis, written in C++ and based on the ROOT package. It provides a common environment for implementation of reconstruction, calibration and filtering procedures, as well as for user-level analyses of Positron Emission Tomography data. The library contains a set of building blocks that can be combined by users with even little programming experience, into chains of processing tasks through a convenient, simple and well-documented API. The generic input-output interface allows processing the data from various sources: low-level data…
In this paper, the Primal-Dual UNet for sparse view CT reconstruction is modified to be applicable to cone beam projections and perform reconstructions of entire volumes instead of slices. Experiments show that the PSNR of the proposed method is increased by 10dB compared to the direct FDK reconstruction and almost 3dB compared to the modified original Primal-Dual Network when using only 23 projections. The presented network is not optimized wrt. memory consumption or hyperparameters but merely serves as a proof of concept and is limited to low resolution projections and volumes.