arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2206.04411astro-ph.SR
收藏

快速日冕物质抛射的偏振研究

Polarimetric Studies of a Fast Coronal Mass Ejection

Marilena Mierla, Bernd Inhester, Andrei N. Zhukov, Sergei V. Shestov, Alessandro Bemporad, Philippe Lamy, Serge Koutchmy

摘要:

在这项工作中,我们进行了一个快速和广泛的日冕物质抛射(CME)的偏振研究所观察到的2012年7月12日的COR 1和COR 2仪器上的太阳地球关系天文台(STEREO)的使命。CME源区是一个X1.4耀斑,从地球的角度观察,位于太阳盘面上大约S15 W 01处。根据3D Graduated Cylindrical Shell(GCS)重建方法,日冕物质抛射的位置在2.5太阳半径的S18 W 00和5.7太阳半径的S 07 W 00附近,这意味着日冕物质抛射在日冕中向外传播时向赤道偏转。CME前缘的预计速度也从低日冕中的约200 km s $^{-1}$发展到COR 2视场中的约1000 km s $^{-1}$。日冕物质抛射的偏振度约为65%,但在某些日冕物质抛射区域可高达80%。CME显示偏振角与切线的偏差在10 $^\circ$ - 15 $^\circ$(或更大)的范围内。我们的分析表明,这主要是由于这样的事实,即三个偏振图像的序列,从那里得到的偏振参数不是同时采取的,但在几秒钟的时间差。在该时间间隔中,CME在仪器的FOV中移动至少两个像素,并且该位移导致偏振参数(偏振度、偏振角等)的不确定性。我们提出了一些改进极化推导的步骤。这项研究对于分析具有偏振能力的仪器的未来数据非常重要。

英文摘要:

In this work we performed a polarimetric study of a fast and wide coronal mass ejection (CME) observed on 12 July 2012 by the COR1 and COR2 instruments onboard Solar TErrestrial RElations Observatory (STEREO) mission. The CME source region was an X1.4 flare located at approximately S15W01 on the solar disk as observed from the Earth's perspective. The position of the CME as derived from the 3D Graduated Cylindrical Shell (GCS) reconstruction method was at around S18W00 at 2.5 solar radii and S07W00 at 5.7 solar radii, meaning that the CME was deflected towards the Equator while propagating outward in the corona. The projected speed of the leading edge of the CME also evolved from around 200 km s$^{-1}$ in the lower corona to around 1000 km s$^{-1}$ in the COR2 field of view. The degree of polarisation of the CME is around 65 % but it can go as high as 80 % in some CME regions. The CME showed deviation of the polarisation angle from the tangential in the range of 10$^\circ$ - 15$^\circ$ (or more). Our analysis showed that this is mostly due to the fact that the sequence of three polarised images from where the polarised parameters are derived is not taken simultaneously, but at a difference of few seconds in time. In this interval of time, the CME is moving by at least two pixels in the FOV of the instruments and this displacement results in uncertainties in the polarisation parameters (degree of polarisation, polarisation angle, etc.). We propose some steps forward to improve the derivation of the polarisation. This study is important for analysing the future data from instruments with polarisation capabilities.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑