AI总结:

本文提出用尺度空间Radon变换(SSRT)建模X射线束以改进CT图像重建,将FBP中的RT频谱替换为SSRT和高斯核,实验表明该方法在低投影数下优于传统RT方法,且对噪声更鲁棒。

摘要:

由于Radon变换(RT)由线积分函数构成,在计算机断层扫描(CT)系统中需做出一些建模假设,这使得图像重建解析方法(如滤波反投影(FBP))对伪影和噪声敏感。另一方面,近期引入了一种新的积分变换,称为尺度空间Radon变换(SSRT),其中RT是其特例。凭借其良好的尺度空间行为等有趣性质,SSRT已催生了许多新应用。本文旨在提高这些方法的重建图像质量,提出用尺度空间Radon变换(SSRT)对X射线束进行建模,其中对CT系统元件物理尺寸的假设更真实地反映了实际情况。在阐述SSRT的基本性质和反演之后,使用FBP算法从SSRT正弦图重建图像,其中FBP中使用的RT频谱被替换为SSRT和高斯核,并在频域中表示。采用PSNR和SSIM作为质量度量,在Shepp-Logan头部模型和拟人腹部模型上比较基于RT和基于SSRT的图像重建。初步结果表明,基于SSRT的方法优于基于RT的方法,尤其是在投影数量减少时,使其更适合需要低剂量辐射的应用,如医用X射线CT。虽然SSRT-FBP和RT-FBP的运行时间大致相同,但实验表明SSRT-FBP对污染CT数据的泊松-高斯噪声更具鲁棒性。

英文摘要:

Since the Radon transform (RT) consists in a line integral function, some modeling assumptions are made on Computed Tomography (CT) system, making image reconstruction analytical methods, such as Filtered Backprojection (FBP), sensitive to artifacts and noise. In the other hand, recently, a new integral transform, called Scale Space Radon Transform (SSRT), is introduced where, RT is a particular case. Thanks to its interesting properties, such as good scale space behavior, the SSRT has known number of new applications. In this paper, with the aim to improve the reconstructed image quality for these methods, we propose to model the X-ray beam with the Scale Space Radon Transform (SSRT) where, the assumptions done on the physical dimensions of the CT system elements reflect better the reality. After depicting the basic properties and the inversion of SSRT, the FBP algorithm is used to reconstruct the image from the SSRT sinogram where the RT spectrum used in FBP is replaced by SSRT and the Gaussian kernel, expressed in their frequency domain. PSNR and SSIM, as quality measures, are used to compare RT and SSRT-based image reconstruction on Shepp-Logan head and anthropomorphic abdominal phantoms. The first findings show that the SSRT-based method outperforms the methods based on RT, especially, when the number of projections is reduced, making it more appropriate for applications requiring low-dose radiation, such as medical X-ray CT. While SSRT-FBP and RT-FBP have utmost the same runtime, the experiments show that SSRT-FBP is more robust to Poisson-Gaussian noise corrupting CT data.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑