Detection of $γ$-ray polarization in Positron Emission Tomography (PET) is as yet an unexploited feature that could be used as an additional handle to improve signal-to-background ratio in this imaging modality. The $γ$ polarization is related to the azimuthal angle in the Compton scattering process, so the initial correlation of polarizations of the annihilation quanta translates to the correlation of the azimuthal angles in events where both annihilation photons undergo Compton scattering. This results in a modulated distribution of the azimuthal angle difference for true events, while this modulation is lacking for the background events. We present a comprehensive experimental study of five detector configurations based on scintillator matrices and silicon photomultipliers, suitable for measuring the azimuthal modulation. The modules consist of either GaGG:Ce or LYSO:Ce pixels with sizes varying from 1.9x1.9x20 $\mathrm{mm^3}$ to 3x3x20 $\mathrm{mm^3}$. The distinctive feature of the modules is that they can reconstruct the Compton scattering by detecting the recoil electron and the scattered gamma in a single detector layer, which simplifies extension to larger systems. The amplitude modulation of the azimuthal angles' difference is clearly observable in all configurations ranging from $0.26\pm0.01$ to $0.34\pm 0.02$ depending on the event selection criteria. The results suggest that finer detector segmentation plays a leading role in achieving higher modulation factors.
Preliminary Study of the Feasibility of a Non Crystalline Positron Emission Tomography Using a Suspension of Superheated Superconducting Grains (SSG) in High Density Dielectric Matrix (HDDM) as Detector
Assessment of a high-resolution candidate detector for prostate time-of-flight positron emission tomography
我们报告使用22 Na源上的MRI兼容的TOF-PET直肠内前列腺探头的探测器元件进行测量,与深度的相互作用的灵敏度。它由LYSO闪烁体晶体制成,用Lumirror包裹,通过硅光电倍增器在两端读出。通过对数据分析过程的详细描述,我们表明我们的结果指向400 ps的重合分辨时间,同时,相互作用深度分辨率为1 mm。这些吸引人的特征,以及微小的1.5 mm x 1.5 mm x 10 mm晶体尺寸,对于原型探针的实现来说非常有希望。
Instituto de Física Corpuscular (IFIC)(粒子物理研究所);Universitat de València(瓦伦西亚大学);Donostia International Physics Center(圣塞巴斯蒂安国际物理中心);Ikerbasque (Basque Foundation for Science)(伊克尔巴斯基(巴斯克科学基金会))
A Proof-of-principle for Time-Of-Flight Positron Emission Tomography Imaging
飞行时间(TOF)是一项在全球范围内用于正电子发射断层成像(PET)成像的重要技术。全世界用于TOF-PET的基于闪烁体的成像系统非常昂贵。多间隙电阻板室(MRPC)是一种易于制造、价格低廉、具有良好位置和时间分辨率的气体探测器。它们可以用作昂贵的制冷剂的合适替代品。为了TOF-PET的唯一目的,已经制造了一对18 cm $\times$ 18 cm、5间隙、玻璃基MRPC模块。我们的主要目的是确定这些制造的MRPC的源(Na-22)的位置的变化。在本文件中,将详细介绍实验结果。
Positron Emission Tomography with quantum-entangled Compton events: first imaging results at clinically relevant activities
University of Zagreb(萨格勒布大学);Institute for Medical Research and Occupational Health(医学研究与职业健康研究所);University Hospital Centre Zagreb(萨格勒布大学医院中心);School of Physics, University of Sydney(悉尼大学物理学院);Instituto de Física Corpuscular (IFIC), CSIC-UV(粒子物理研究所(IFIC),西班牙国家研究委员会-瓦伦西亚大学)