arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2204.12539physics.med-phcs.AI
收藏

直肠癌放射治疗计划的自动化

Automation of Radiation Treatment Planning for Rectal Cancer

The University of Texas MD Anderson Cancer Center(德克萨斯大学MD安德森癌症中心);The University of Alabama at Birmingham(阿拉巴马大学伯明翰分校);Tygerberg Hospital(泰格堡医院);University of Stellenbosch(斯泰伦博斯大学)
Kai Huang, Prajnan Das, Adenike M. Olanrewaju, Carlos Cardenas, David Fuentes, Lifei Zhang, Donald Hancock, Hannah Simonds, Dong Joo Rhee, Sam Beddar, Tina Mari… 展开作者

Kai Huang, Prajnan Das, Adenike M. Olanrewaju, Carlos Cardenas, David Fuentes, Lifei Zhang, Donald Hancock, Hannah Simonds, Dong Joo Rhee, Sam Beddar, Tina Marie Briere, Laurence Court

摘要:

为直肠癌三维适形放疗治疗计划开发一个自动化工作流程,该工作流程结合了深度学习(DL)孔径预测和前瞻性计划算法。我们设计了一种算法来自动化临床工作流程,以进行现场规划。DL模型在555名患者身上进行了训练、验证和测试,以自动生成主野和增强野的孔径形状。网络输入是数字重建X线摄影、大体肿瘤体积(GTV)和淋巴结GTV。医生对20名患者的每个孔进行5分制评分(>3分可接受)。然后开发了一种计划算法,使用楔形和子野的组合来创建均匀剂量。该算法迭代地识别热点体积,创建子场,并优化射束权重,所有这些都无需用户干预。使用具有不同设置的临床孔径在20名患者上测试该算法,并且由医生对所得到的计划(4个计划/患者)进行评分。医生使用DL生成的孔径和计划算法对39名患者的端到端工作流程进行了测试和评分。预测孔径的Dice评分分别为0.95、0.94和0.90,用于后-前、双射野和增强射野。100%、95%和87.5%的后-前、后和增强孔径分别被评为临床可接受。楔形和非楔形计划分别有85%和50%的患者在临床上可接受。最终计划热点剂量百分比从处方剂量的121%($\pm$ 14%)降至109%($\pm$ 5%)。自动生成孔径的集成端到端工作流程和优化的场中场规划为38/39(97%)的患者提供了临床可接受的计划。我们已经成功地自动化了临床工作流程,为我们的机构生成直肠癌放射治疗计划。

英文摘要:

To develop an automated workflow for rectal cancer three-dimensional conformal radiotherapy treatment planning that combines deep-learning(DL) aperture predictions and forward-planning algorithms. We designed an algorithm to automate the clinical workflow for planning with field-in-field. DL models were trained, validated, and tested on 555 patients to automatically generate aperture shapes for primary and boost fields. Network inputs were digitally reconstructed radiography, gross tumor volume(GTV), and nodal GTV. A physician scored each aperture for 20 patients on a 5-point scale(>3 acceptable). A planning algorithm was then developed to create a homogeneous dose using a combination of wedges and subfields. The algorithm iteratively identifies a hotspot volume, creates a subfield, and optimizes beam weight all without user intervention. The algorithm was tested on 20 patients using clinical apertures with different settings, and the resulting plans(4 plans/patient) were scored by a physician. The end-to-end workflow was tested and scored by a physician on 39 patients using DL-generated apertures and planning algorithms. The predicted apertures had Dice scores of 0.95, 0.94, and 0.90 for posterior-anterior, laterals, and boost fields, respectively. 100%, 95%, and 87.5% of the posterior-anterior, laterals, and boost apertures were scored as clinically acceptable, respectively. Wedged and non-wedged plans were clinically acceptable for 85% and 50% of patients, respectively. The final plans hotspot dose percentage was reduced from 121%($\pm$ 14%) to 109%($\pm$ 5%) of prescription dose. The integrated end-to-end workflow of automatically generated apertures and optimized field-in-field planning gave clinically acceptable plans for 38/39(97%) of patients. We have successfully automated the clinical workflow for generating radiotherapy plans for rectal cancer for our institution.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑