经颅电流刺激电场分析的准静态近似误差

Quasi-Static Approximation Error of Electric Field Analysis for Transcranial Current Stimulation

Gabriel Gaugain, Lorette Quéguiner, Marom Bikson, Ronan Sauleau, Maxim Zhadobov, Julien Modolo, Denys Nikolayev

摘要:

目的:由经颅交流电刺激(tACS)诱导的电场的数值建模目前是预测和理解神经反应的标准程序的一部分。为了减少计算量,一般采用准静态近似计算电场。在这里,我们的目的是分析和量化的近似在一个广泛的频率范围内的有效性。方法:我们使用解剖头部模型进行电磁建模研究,并考虑假设纯欧姆介质(即,静态公式)或有损耗介电介质(准静态公式)。在谐波和脉冲信号的情况下,与麦克斯韦方程组的解进行了比较。最后分析了电极位置对这些误差的影响。主要结果:我们的研究结果表明,准静态近似是有效的,并产生一个相对误差低于1%,高达1.43 MHz。最大的误差是在静态情况下引入的,其中误差在整个考虑的频谱上超过1%,并且在10 Hz时在大脑中高达20%。我们还强调了考虑组织的电容效应对脉冲波形的特殊重要性,这可以防止由纯欧姆近似引起的信号失真。在神经元水平上,结果指出在聚焦点处感觉电场的差异高达22%,影响锥体细胞的放电时间。意义:准静态近似在当前用于tACS的频率范围内仍然有效。然而,忽略介电常数(静态公式)对于谐波和非谐波信号都引入显著误差。指出了准确的tCS数值模拟需要可靠的低频介电数据。

英文摘要:

Objective: Numerical modeling of electric fields induced by transcranial alternating current stimulation (tACS) is currently a part of the standard procedure to predict and understand neural response. Quasi-static approximation for electric field calculations is generally applied to reduce the computational cost. Here, we aimed to analyze and quantify the validity of the approximation over a broad frequency range. Approach: We performed electromagnetic modeling studies using an anatomical head models and considered approximations assuming either a purely ohmic medium (i.e., static formulation) or a lossy dielectric medium (quasi-static formulation). The results were compared with the solution of Maxwell's equations in the cases of harmonic and pulsed signals. Finally, we analyzed the effect of electrode positioning on these errors. Main Results: Our findings demonstrate that the quasi-static approximation is valid and produces a relative error below 1% up to 1.43 MHz. The largest error is introduced in the static case, where the error is over 1% across the entire considered spectrum and as high as 20% in the brain at 10 Hz. We also highlight the special importance of considering the capacitive effect of tissues for pulsed waveforms, which prevents signal distortion induced by the purely ohmic approximation. At the neuron level, the results point a difference of sense electric field as high as 22% at focusing point, impacting pyramidal cells firing times. Significance: Quasi-static approximation remains valid in the frequency range currently used for tACS. However, neglecting permittivity (static formulation) introduces significant error for both harmonic and non-harmonic signals. It points out that reliable low frequency dielectric data are needed for accurate tCS numerical modeling.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑