环境空气中加速、稳态和衰退负流注的计算研究

A computational study of accelerating, steady and fading negative streamers in ambient air

Baohong Guo, Xiaoran Li, Ute Ebert, Jannis Teunissen

AI总结:

本研究基于二维轴对称流体模型,探讨了环境空气中负流注的加速、稳态和衰退传播模式,重点揭示了稳态负流注在特定电场范围内的不稳定传播特性及其与正流注在速度、光学直径等性质上的显著差异。

摘要:

我们使用二维轴对称流体模型研究环境空气中的负流注。根据背景电场,我们观察到加速、稳态和衰退负流注。衰退发生在低背景电场中,此时负流注失去其电场增强作用,且其速度变得与最大电子漂移速度相当。我们的重点是稳态传播模式,在此期间流注的半径和速度等性质几乎不变。然而,该模式是不稳定的,即条件的微小变化会导致加速或减速。我们在 9.19 kV/cm 至 15.75 kV/cm 的背景电场中观察到稳态负流注,表明不存在唯一的稳态传播电场(或稳定性电场)。另一发现是,稳态负流注能够持续传播数十厘米,其头部后方仅有有限的导电长度,这与稳态正流注相似。我们观察到光学直径与流注速度及流注头电位等性质之间存在近似线性关系。根据这些线性关系,我们得出稳态负流注最小光学直径的粗略下限约为 0.27 mm 至 0.35 mm。可获得稳态负流注的最低背景电场为 9.19 kV/cm。相比之下,最近在低至 4.05 kV/cm 的背景电场中获得了稳态正流注。我们发现稳态负流注与正流注的性质存在显著差异。例如,对于稳态负流注,流注速度与最大电子漂移速度之比约为 2 至 4.5,而对于稳态正流注,该比值约为 0.05 至 0.26。

英文摘要:

We study negative streamers in ambient air using a 2D axisymmetric fluid model. Depending on the background electric field, we observe accelerating, steady and fading negative streamers. Fading occurs in low background fields, when negative streamers lose their field enhancement and when their velocities become comparable to their maximal electron drift velocities. Our focus is on the steady propagation mode, during which streamer properties like radius and velocity hardly change. However, this mode is unstable, in the sense that a small change in conditions leads to acceleration or deceleration. We observe steady negative streamers in background fields ranging from 9.19 kV/cm to 15.75 kV/cm, indicating that there is no unique steady propagation field (or stability field). Another finding is that steady negative streamers are able to keep propagating over tens of centimeters, with only a finite conductive length behind their heads, similar to steady positive streamers. Approximately linear relationships are observed between the optical diameter and properties like the streamer velocity and the streamer head potential. From these linear relations, we obtain rough lower bounds of about 0.27 mm to 0.35 mm for the minimal optical diameter of steady negative streamers. The lowest background field in which a steady negative streamer could be obtained is 9.19 kV/cm. In contrast, steady positive streamers have recently been obtained in a background field as low as 4.05 kV/cm. We find that the properties of steady negative and positive streamers differ significantly. For example, for steady negative streamers the ratio between streamer velocity and maximal electron drift velocity ranges from about 2 to 4.5, whereas for steady positive streamers this ratio ranges from about 0.05 to 0.26.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑