用于PET成像的创新型$^{52g}$Mn:产生截面建模与剂量学评估
The innovative $^{52g}$Mn for PET imaging: production cross section modeling and dosimetric evaluation
AI总结:
本研究通过Talys优化$^{nat}$V($α$,x)$^{52g}$Mn截面并结合OLINDA剂量评估,证明该途径比标准$^{nat}$Cr($p$,x)产额更高、纯度更高且剂量增加更低。
摘要:
背景:最近,$^{nat}$V($α$,x)$^{52g}$Mn反应被提出作为标准$^{nat}$Cr($p$,x)$^{52g}$Mn反应的一种可能替代方案,但为了更好地比较这两种产生途径,需要改进建模。目的:本工作聚焦于开发精确的模拟和模型,以从活度量和放射性核素纯度(RNP)方面,以及相对于纯$^{52g}$MnCl$_2$注射时由共同产生的放射性污染物导致的剂量增加(DI)方面,比较两种反应产生的$^{52g}$Mn。方法:采用核程序代码Talys,通过调节微观能级密度参数来优化$^{nat}$V($α$,x)$^{52g}$Mn截面。使用OLINDA软件2.2.0并采用女性和男性体模完成了[$^{xx}$Mn]Cl$_2$的剂量学评估。最后,将两种产生途径估算的$^{xx}$Mn放射性同位素产额与剂量学结果相结合,以评估辐照结束后不同时间的DI。结果:截面计算与测量结果取得了良好一致。两种反应通道的比较表明,$^{nat}$V($α$,x)$^{52g}$Mn带来更高的产额和更高的纯度,从而在DI方面对患者健康产生较小的有害影响。结论:$^{nat}$V($α$,x)和$^{nat}$Cr($p$,x)两种产生途径都能提供临床可接受的、用于PET成像的$^{52g}$MnCl$_2$。然而,$^{nat}$V($α$,x)$^{52g}$Mn反应给出的DI系统性地低于$^{nat}$Cr($p$,x)$^{52g}$Mn可获得的DI,并且具有更长的临床可用时间窗(RNP ≥ 99%)。
英文摘要:
Background: Recently, the reaction $^{nat}$V($α$,x)$^{52g}$Mn has been proposed as a possible alternative to the standard $^{nat}$Cr($p$,x)$^{52g}$Mn one, but improvements in the modeling were needed to better compare the two production routes. Purpose: This work focuses on the development of precise simulations and models to compare the $^{52g}$Mn production from both reactions in terms of amount of activity and radionuclidic purity (RNP), as well as in terms of dose increase (DI) due to the co-produced radioactive contaminants, with respect to a pure $^{52g}$MnCl$_2$ injection. Methods: The nuclear code Talys has been employed to optimize the $^{nat}$V($α$,x)$^{52g}$Mn cross section by tuning the parameters of the microscopic level densities. Dosimetric assessments of [$^{xx}$Mn]Cl$_2$ have been accomplished with OLINDA software 2.2.0 using female and male phantoms. At the end, the yield of $^{xx}$Mn radioisotopes estimated for the two production routes have been combined with the dosimetric results, to assess the DI at different times after the end of the irradiation. Results: Good agreement was obtained between cross sections calculations and measurements. The comparison of the two reaction channels suggests that $^{nat}$V($α$,x)$^{52g}$Mn leads to higher yield and higher purity, resulting in a less harmful impact on patients' health in terms of DI. Conclusions: Both $^{nat}$V($α$,x) and $^{nat}$Cr($p$,x) production routes provide clinically acceptable $^{52g}$MnCl$_2$ for PET imaging. However, the $^{nat}$V($α$,x)$^{52g}$Mn reaction provides a DI systematically lower than the one obtainable with $^{nat}$Cr($p$,x)$^{52g}$Mn and a longer time window in which it can be used clinically (RNP $\ge$ 99\%).
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。